The Bio-Chemistry Analyzer is mainly used for the quantitative analysis of the clinical bio-chemical items; it applies the lamber- beer law: A=kbc=lg(i0/i).
Among them: a: absorbency, k: aspirated index, b: liquid layer’s thickness, c: solution’s consistency, i0: incident light’s strength, i: transmit light’s strength.

According to the above formulas, under the condition of the certain liquid layer’s thickness and incident light’s strength, as long as test the strength of transmit light which goes through the liquid, so we can calculate the consistency of the solution.


Technical parameters condition for operation
Temperature 10°C-35°C
Relative humidity 20 – 90 %.
Power 85-264V

Conserved Transportation Condition:
Temperature 0°C-40°C
Relative humidity 10%-90 %.

Technical parameters:
  • Method: kinetic. 
  • End-point, linearity, plus time, non linearity plus time, absorbency, sample blank, multi-standard, velocity, calculation, two-point, double wavelength etc.
  • 7 wavelengths optic system avoiding outer disturbance.
  • Wavelength range: 340-700nm
  • Quality control: quality control for all tests, statistic and print quality control parameters automatically with QC curves. Every test can do high medium low three groups quality control.
  • Program: add or delete test items easily according to the condition. Modify the test parameters. Display dynamic curves at real time. 
  • The print content includes comprehensive hospital's name and sample' materials. Dormant automatically for the lamp to prolong it's life span/input 
  • 8 standard curves at most in testing with multi standard method.
Test items ≥200filter
Wavelengths 340. 380. 405. 505. 546. 578. 620nm, 1 empty position wavelength
Precision ±2NM.
Photometric range -0. 2 – 2. 3 abs.
Flow cell quartz .
Measure volume 32ULL 
lamp quartz-halogen lamp, 6V 10W.
Liquid thickness 10mm.
Screen 240×128 dots graphic LCD.
Output inner thermal printer or external parallel printer optional
Out-printer print A4 paper result report.
Thermal paper dimension diameter 35mm,width: 78mm(3inches)aspirating samples 
Volume ≥ 500UL,
Adjustable memory 500 samples or quality controls. ≤30 tests per sample. 
Communications connector RS-232 serial.
Dimension 33cm in length×35. 5cm in width×12. 59cm in height
weight 8kg.
 
Ordering Details
Catalogue No. Description
JLT-1200 Bio Chemistry Analyser
 
Description

Details

BIO CHEMISTRY ANALYSER

The Bio-Chemistry Analyzer is mainly used for the quantitative analysis of the clinical bio-chemical items; it applies the lamber- beer law: A=kbc=lg(i0/i).
Among them: a: absorbency, k: aspirated index, b: liquid layer’s thickness, c: solution’s consistency, i0: incident light’s strength, i: transmit light’s strength.

According to the above formulas, under the condition of the certain liquid layer’s thickness and incident light’s strength, as long as test the strength of transmit light which goes through the liquid, so we can calculate the consistency of the solution.


Technical parameters condition for operation
Temperature 10°C-35°C
Relative humidity 20 – 90 %.
Power 85-264V

Conserved Transportation Condition:
Temperature 0°C-40°C
Relative humidity 10%-90 %.

Technical parameters:
  • Method: kinetic. 
  • End-point, linearity, plus time, non linearity plus time, absorbency, sample blank, multi-standard, velocity, calculation, two-point, double wavelength etc.
  • 7 wavelengths optic system avoiding outer disturbance.
  • Wavelength range: 340-700nm
  • Quality control: quality control for all tests, statistic and print quality control parameters automatically with QC curves. Every test can do high medium low three groups quality control.
  • Program: add or delete test items easily according to the condition. Modify the test parameters. Display dynamic curves at real time. 
  • The print content includes comprehensive hospital's name and sample' materials. Dormant automatically for the lamp to prolong it's life span/input 
  • 8 standard curves at most in testing with multi standard method.
Test items ≥200filter
Wavelengths 340. 380. 405. 505. 546. 578. 620nm, 1 empty position wavelength
Precision ±2NM.
Photometric range -0. 2 – 2. 3 abs.
Flow cell quartz .
Measure volume 32ULL 
lamp quartz-halogen lamp, 6V 10W.
Liquid thickness 10mm.
Screen 240×128 dots graphic LCD.
Output inner thermal printer or external parallel printer optional
Out-printer print A4 paper result report.
Thermal paper dimension diameter 35mm,width: 78mm(3inches)aspirating samples 
Volume ≥ 500UL,
Adjustable memory 500 samples or quality controls. ≤30 tests per sample. 
Communications connector RS-232 serial.
Dimension 33cm in length×35. 5cm in width×12. 59cm in height
weight 8kg.
 
Ordering Details
Catalogue No. Description
JLT-1200 Bio Chemistry Analyser
 