- Description
-
Details
LabSmith902 Benchtop pH/Conductivity/TDS/Salinity Meter
Multiparameter benchtop pH/Conductivity meter contains 12 optional parameters. The meter is suitable for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.
pH Mode:
• Profession benchtop pH/Conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolts measurement modes provide accurate ORP readings.
Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.Ordering Information with Technical Specifications:
Catalogue No. LabSmith902 pH Range -2.000~20.000pH Accuracy ±0.002pH Resolution 0.1, 0.01, 0.001pH, Selectable Calibration Points 1 to 5 points Calibration Solutions USA, NIST, DIN or User-defined Temperature Compensation 0~100°C, 32~212°F Compensation Mode Manual or Automatic mV Range -1999.9~1999.9mV Accuracy ±0.2mV Resolution 0.1, 1mV, Selectable Calibration Points 1 point (Only for Relative mV mode) Calibration Range ±200mV Conductivity Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm Accuracy ±0.5% F.S Calibration Points 1 to 5 points Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic Temperature Coefficient 0.0~10.0%/°C Compensation Modes Linear or Pure Water Cell Constant K=0.1, 1, 10 or User-defined Normalization Temperature 20°C or 25°C TDS Range 0~100ppt (Max. 200ppt, depending on factor setting) Accuracy ±1% F.S TDS Factor 0.1~1.0 (Default 0.5) Salinity Range 0~10ppt (Max. 80ppt) Accuracy ±1% F.S Measurement Modes Seawater or Practical Salinity Resistivity Range 0~100MΩ Accuracy ±1% F.S Resolution 0.01, 0.1, 1 Temperature Range 0~105°C, 32~221°F Accuracy ±0.5°C, ±0.9°F Resolution 0.1°C Calibration Points 1 point Calibration Range Measured value ±10°C Others Hold Function Manual or Automatic Stability Conditions Low or High Calibration Due 0 to 31 days Power Off Manual or Automatic (10, 20, 30 minutes) Reset Function Yes Memory Stores up to 500 data sets Output USB Communication Interface Connector BNC, 6-pin Mini Plug Display LCD (130×110mm) Power Requirements DC5V, using AC adapter, 220VAC/50Hz Dimensions 210(L)×188(W)×60(H)mm Weight 1.5kg Accessories:
Catalogue No. Accessories LabSmith902-CN E201-BNC pH Electrode CON-1 Conductivity Electrode TP-10K Temperature Probe pH Buffer Pouches (pH4.01/7.00/10.01) Conductivity Standard Solutions (84µS, 1413µS, 12.88mS) USB Cable DC5V Power Adapter LabSmith902-UK P11 Glass pH Electrode (Made in UK) K10 Conductivity Electrode (Made in UK) TP-10K Temperature Probe pH Buffer Pouches (pH4.01/7.00/10.01) Conductivity Standard Solutions (84µS, 1413µS, 12.88mS) USB Cable DC5V Power Adapter - Additional Information
-
Additional Information
Code No - Reviews
-