jainsonsindia partners
 Enquiry Cart

LabSmith902 Benchtop pH/Conductivity/TDS/Salinity Meter

More Views

LabSmith902 Benchtop pH/Conductivity/TDS/Salinity Meter

Code:

LabSmith902 Benchtop pH/Conductivity/TDS/Salinity Meter

Multiparameter benchtop pH/Conductivity meter contains 12 optional parameters. The meter is suitable for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.

pH Mode:
• Profession benchtop pH/Conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolts measurement modes provide accurate ORP readings.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Ordering Information with Technical Specifications:

Catalogue No. LabSmith902
pH  
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV  
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range ±200mV
Conductivity  
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS  
Range 0~100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Salinity  
Range 0~10ppt (Max. 80ppt)
Accuracy ±1% F.S
Measurement Modes Seawater or Practical Salinity
Resistivity  
Range 0~100MΩ
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
Temperature  
Range 0~105°C, 32~221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C
Calibration Points 1 point
Calibration Range Measured value ±10°C
Others  
Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 to 31 days
Power Off Manual or Automatic (10, 20, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC, 6-pin Mini Plug
Display LCD (130×110mm)
Power Requirements DC5V, using AC adapter, 220VAC/50Hz
Dimensions 210(L)×188(W)×60(H)mm
Weight 1.5kg

 

Accessories:

Catalogue No. Accessories
LabSmith902-CN E201-BNC pH Electrode
CON-1 Conductivity Electrode
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
USB Cable
DC5V Power Adapter
LabSmith902-UK P11 Glass pH Electrode (Made in UK)
K10 Conductivity Electrode (Made in UK)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
USB Cable
DC5V Power Adapter
Description

Details

LabSmith902 Benchtop pH/Conductivity/TDS/Salinity Meter

Multiparameter benchtop pH/Conductivity meter contains 12 optional parameters. The meter is suitable for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.

pH Mode:
• Profession benchtop pH/Conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolts measurement modes provide accurate ORP readings.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 12 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Ordering Information with Technical Specifications:

Catalogue No. LabSmith902
pH  
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV  
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range ±200mV
Conductivity  
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS  
Range 0~100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Salinity  
Range 0~10ppt (Max. 80ppt)
Accuracy ±1% F.S
Measurement Modes Seawater or Practical Salinity
Resistivity  
Range 0~100MΩ
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
Temperature  
Range 0~105°C, 32~221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C
Calibration Points 1 point
Calibration Range Measured value ±10°C
Others  
Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 to 31 days
Power Off Manual or Automatic (10, 20, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC, 6-pin Mini Plug
Display LCD (130×110mm)
Power Requirements DC5V, using AC adapter, 220VAC/50Hz
Dimensions 210(L)×188(W)×60(H)mm
Weight 1.5kg

 

Accessories:

Catalogue No. Accessories
LabSmith902-CN E201-BNC pH Electrode
CON-1 Conductivity Electrode
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
USB Cable
DC5V Power Adapter
LabSmith902-UK P11 Glass pH Electrode (Made in UK)
K10 Conductivity Electrode (Made in UK)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
USB Cable
DC5V Power Adapter
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:245 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 245