jainsonsindia partners
 Enquiry Cart

LabSmith900 Benchtop Multiparameter Water Quality Meter

More Views

LabSmith900 Benchtop Multiparameter Water Quality Meter

Code:

LabSmith900 Benchtop Multiparameter Water Quality Meter

Multiparameter water quality meter contains 15 optional parameters. The meter is suitable for measuring the pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity and DO of the liquids.

pH Mode:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolts measurement modes provide accurate ORP readings.

Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units include the ppm, mg/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
  factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy. 

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Ordering Information with Technical Specifications:

Catalogue No. LabSmith900
pH  
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV  
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range ±200mV
Ion  
Range 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)
Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 2 to 5 points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
Conductivity  
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS  
Range 0~100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Salinity  
Range 0~10ppt (Max. 80ppt)
Accuracy ±1% F.S
Measurement Modes Seawater or Practical Salinity
Resistivity  
Range 0~100MΩ
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
Dissolved Oxygen  
Range 0.00~20.00mg/L (or ppm)
Accuracy ±0.2mg/L
Resolution 0.01mg/L
Calibration Points 1 or 2 points
Temperature Compensation 0~50°C, 32~122°F, Automatic
Pressure Correction 60.0~112.5kPa, 450~850mmHg
Salinity Correction 0~50g/L
% Saturation of Oxygen  
Range 0.0~200.0%
Accuracy ±2.0%
Resolution 0.1, 1%
Temperature  
Range 0~105°C, 32~221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C
Calibration Points 1 point
Calibration Range Measured value ±10°C
Others  
Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 to 31 days
Power Off Manual or Automatic (10, 20, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC, 6-pin Mini Plug
Display LCD (130×110mm)
Power Requirements DC5V, using AC adapter, 220VAC/50Hz
Dimensions 210(L)×188(W)×60(H)mm
Weight 1.5kg

 

Accessories:

Order Code Accessories
LabSmith900-CN E201-BNC pH Electrode
CON-1 Conductivity Electrode
DO100 Dissolved Oxygen Probe (Made in US)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
DO Electrolyte Solution
DO Membrane Cap
USB Cable
DC5V Power Adapter
LabSmith900-UK P11 Glass pH Electrode (Made in UK)
K10 Conductivity Electrode (Made in UK)
DO100 Dissolved Oxygen Probe (Made in US)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
DO Electrolyte Solution
DO Membrane Cap
USB Cable
DC5V Power Adapter
Description

Details

LabSmith900 Benchtop Multiparameter Water Quality Meter

Multiparameter water quality meter contains 15 optional parameters. The meter is suitable for measuring the pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity and DO of the liquids.

pH Mode:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolts measurement modes provide accurate ORP readings.

Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units include the ppm, mg/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
  factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy. 

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the number of calibration points, resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Ordering Information with Technical Specifications:

Catalogue No. LabSmith900
pH  
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV  
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range ±200mV
Ion  
Range 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)
Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 2 to 5 points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
Conductivity  
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS  
Range 0~100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Salinity  
Range 0~10ppt (Max. 80ppt)
Accuracy ±1% F.S
Measurement Modes Seawater or Practical Salinity
Resistivity  
Range 0~100MΩ
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
Dissolved Oxygen  
Range 0.00~20.00mg/L (or ppm)
Accuracy ±0.2mg/L
Resolution 0.01mg/L
Calibration Points 1 or 2 points
Temperature Compensation 0~50°C, 32~122°F, Automatic
Pressure Correction 60.0~112.5kPa, 450~850mmHg
Salinity Correction 0~50g/L
% Saturation of Oxygen  
Range 0.0~200.0%
Accuracy ±2.0%
Resolution 0.1, 1%
Temperature  
Range 0~105°C, 32~221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C
Calibration Points 1 point
Calibration Range Measured value ±10°C
Others  
Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 to 31 days
Power Off Manual or Automatic (10, 20, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC, 6-pin Mini Plug
Display LCD (130×110mm)
Power Requirements DC5V, using AC adapter, 220VAC/50Hz
Dimensions 210(L)×188(W)×60(H)mm
Weight 1.5kg

 

Accessories:

Order Code Accessories
LabSmith900-CN E201-BNC pH Electrode
CON-1 Conductivity Electrode
DO100 Dissolved Oxygen Probe (Made in US)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
DO Electrolyte Solution
DO Membrane Cap
USB Cable
DC5V Power Adapter
LabSmith900-UK P11 Glass pH Electrode (Made in UK)
K10 Conductivity Electrode (Made in UK)
DO100 Dissolved Oxygen Probe (Made in US)
TP-10K Temperature Probe
pH Buffer Pouches (pH4.01/7.00/10.01)
Conductivity Standard Solutions (84µS, 1413µS, 12.88mS)
DO Electrolyte Solution
DO Membrane Cap
USB Cable
DC5V Power Adapter
Additional Information

Additional Information

Code No
Reviews