jainsonsindia partners
 Enquiry Cart

Water Quality Analyser

Code:

Water Quality Analyser

LS-PE138, Microprocessor based Multi Parameter Water Quality Analyser. Measures directly pH, EMF, Temperature, Electrolyte Conductivity (EC), Total Dissolved Solids (TDS), Dissolve Oxygen (DO) & Salinity, Colorimetric, Abs./%T and Turbidity in Water Sample one at a time.

SALIENT FEATURES

  • Light weight, Portable and Easy to carry on field
  • Unique DO measurement in Air saturated waters using Conventional Polarographic Probe.
  • Programmable Calibration upto 3 points for pH with Memory Back-up.
  • Userful for Potentiometric & Redox measurements.
  • Automatic / Manual Temperature Compensation.
  • Accurate & Highly Stable.
  • Elegantly styled into a Briefcase for operational convenience in Field.
  • Operates on Rechargeable Battery & Mains Supply.

TECHNICAL SPECIFICATIONS

 PARAMETER  pH EMF (mV) Temp (°C) Salinity
 Range  0 to 14 ±1999.9 0 to 100 0 to 40 ppt
 Readability  0.001 0.1 0.1 --
 Accuracy  ±0.001* ±0.1 ±0.5 ±1%(1)
 Repeatablility  ±0.001 ±0.1 ±0.1 --
 INPUT
 Sensor  CE/GE & RE CE/GE & RE Semiconductor ISE (Cl) & RE
 Impedance@25°C  >1013 >1013 -- --
 Receptacle  BNC, Banana BNC, Banana Banana BNC
 Temp. Compensation  0 to 100°C A/M -- -- 0 to 50°C A/M
 PARAMETER  EC  TDS  DO (ppm)  COLORIMETER  TURBIDITY
 Range  0 to 200mS, 5 ranges  0 to 100 ppt 5 ranges at TDS factor 0.5  0 to 20  ±2 Abs., 0 to 100 %T  0 to 100 NTU**
 Readability  0.05 % of range  0.05 % of range  0.1  0.001 Abs  0.1
 Accuracy  ±1% of range  ±1% of range  ±0.1  ±0.05 Abs  ±2%
 Repeatablility  ±0.5 % of range  ±0.5 % of range  ±0.1  ±0.01 Abs  ±1%
 INPUT
 Sensor  Conductivity Cell  Conductivity Cell  Polarographic  Silicon PhotoDiode  Silicon PhotoDiode
 Impedance@25°C  1 KHz Sine Wave  1 KHz Sine Wave  DC Voltage  Tungsten Lamp  Tungsten Lamp
 Receptacle  BNC  BNC  BNC  --  --
 Temp. Compensation  0 to 50°C A/M  0 to 50°C A/M  0 to 100°C A/M  --  --

* Conforms to IS2711-1979.
** Based on Formazine (Hydrazine Suphate and Hexamine) Standard
(1) Depending on the Standards
(2) Excluding 300 mm height electrode stand of 0.1 kg weight.
A : Automatic
GE : Glass Electrode
CE : Combined pH Electrode
M : Manual
RE : Reference Electrode
ISE : Ion Selective Electrode

Ordering Information:
Catalogue No.:   LS-PE 138  
Product Name:  Water Quality Analyzer
Description

Details

Water Quality Analyser

LS-PE138, Microprocessor based Multi Parameter Water Quality Analyser. Measures directly pH, EMF, Temperature, Electrolyte Conductivity (EC), Total Dissolved Solids (TDS), Dissolve Oxygen (DO) & Salinity, Colorimetric, Abs./%T and Turbidity in Water Sample one at a time.

SALIENT FEATURES

  • Light weight, Portable and Easy to carry on field
  • Unique DO measurement in Air saturated waters using Conventional Polarographic Probe.
  • Programmable Calibration upto 3 points for pH with Memory Back-up.
  • Userful for Potentiometric & Redox measurements.
  • Automatic / Manual Temperature Compensation.
  • Accurate & Highly Stable.
  • Elegantly styled into a Briefcase for operational convenience in Field.
  • Operates on Rechargeable Battery & Mains Supply.

TECHNICAL SPECIFICATIONS

 PARAMETER  pH EMF (mV) Temp (°C) Salinity
 Range  0 to 14 ±1999.9 0 to 100 0 to 40 ppt
 Readability  0.001 0.1 0.1 --
 Accuracy  ±0.001* ±0.1 ±0.5 ±1%(1)
 Repeatablility  ±0.001 ±0.1 ±0.1 --
 INPUT
 Sensor  CE/GE & RE CE/GE & RE Semiconductor ISE (Cl) & RE
 Impedance@25°C  >1013 >1013 -- --
 Receptacle  BNC, Banana BNC, Banana Banana BNC
 Temp. Compensation  0 to 100°C A/M -- -- 0 to 50°C A/M
 PARAMETER  EC  TDS  DO (ppm)  COLORIMETER  TURBIDITY
 Range  0 to 200mS, 5 ranges  0 to 100 ppt 5 ranges at TDS factor 0.5  0 to 20  ±2 Abs., 0 to 100 %T  0 to 100 NTU**
 Readability  0.05 % of range  0.05 % of range  0.1  0.001 Abs  0.1
 Accuracy  ±1% of range  ±1% of range  ±0.1  ±0.05 Abs  ±2%
 Repeatablility  ±0.5 % of range  ±0.5 % of range  ±0.1  ±0.01 Abs  ±1%
 INPUT
 Sensor  Conductivity Cell  Conductivity Cell  Polarographic  Silicon PhotoDiode  Silicon PhotoDiode
 Impedance@25°C  1 KHz Sine Wave  1 KHz Sine Wave  DC Voltage  Tungsten Lamp  Tungsten Lamp
 Receptacle  BNC  BNC  BNC  --  --
 Temp. Compensation  0 to 50°C A/M  0 to 50°C A/M  0 to 100°C A/M  --  --

* Conforms to IS2711-1979.
** Based on Formazine (Hydrazine Suphate and Hexamine) Standard
(1) Depending on the Standards
(2) Excluding 300 mm height electrode stand of 0.1 kg weight.
A : Automatic
GE : Glass Electrode
CE : Combined pH Electrode
M : Manual
RE : Reference Electrode
ISE : Ion Selective Electrode

Ordering Information:
Catalogue No.:   LS-PE 138  
Product Name:  Water Quality Analyzer
Additional Information

Additional Information

Code No