jainsonsindia partners
 Enquiry Cart

Polarimeter

Code:
Polarimeter
ADVANCE has been designing and manufacturing precision Polarimeters and Saccharimeters for the last 40 years. This experience ensures the best and latest in Polarimeter technology, designs and features are incorporated in our instruments. Polarimeters are used for the determination of the Optical Rotation of all Optically Active substances and used in testing Pharmaceuticals, Chemicals, Essential Oils, Sugars, Foodstuffs, Brewery products etc.. The Polarimeters and Saccharimeters are available in two series. The PA Series is suitable for observation tubes up to 220mm while PB series can accommodate tubes upto 400 mm. They offer an accuracy of 0.01°Angular Scale and 0.5°ISS.

An outstanding feature of ADVANCE Polarimeters is the incorporation of precision glass scale and scale plate with minutely finished rotating mechanism and Tropic proof highly sensitive optical system. The test result can be read precisely and directly without the aid of a vernier and its associated errors. The latest addition is use of an Integrated Lighting System, in place of the bulky and fragile Sodium Lamp, which gives the advantage of immediate illumination while saving table space and electrical power.
Key Features
The advance optical system of the Polarimeters and Saccharimeters have been designed in order to minimize the destructive influences of a hot and humid climate and abrupt temperature changes on the sensitive optics and are suitable for use in Tropical conditions. Superior quality Optics & highly sensitive Triple Shadow with improved definition offers the advantages such as Permanent focus with difficult and dark liquids High accuracy and repeatability along with strain free viewing
  • Polarimeters and Saccharimeters have been designed in order to minimize the destructive influences of a hot and humid climate and abrupt temperature changes on the sensitive optics and are suitable for use in Tropical conditions.
  • The latest addition is use of an Integrated Lighting System, in place of the bulky and fragile Sodium Lamp, which gives the advantage of immediate illumination while saving table space and electrical power.
  • Superior quality triple shadow system
  • Triple Shadow System rotates with the circle thus affording immediate indication of the direction of the material being examined.
  • Permanent focus with difficult and dark liquids
  • High accuracy and repeatability along with strain free viewing
Technical Specifications*
Instrument Name Polarimeter Polarimeter Polarimeter Polarimeter/Saccharimeter Polarimeter/Saccharimeter
Model No. LSPA-2 LSPA-1R (Standard) LSPA-1R (Deluxe) LSPB-1R / PB-4(Standard) LSPB-1R / PB-4(Deluxe)
Tube Length (Maximum) 220 mm 220 mm 220mm 400mm 400mm
Shadow System Half/Triple Shadow Improved Triple Shadow Improved Triple Shadow & High Improved Triple Shadow Improved Triple Shadow & High
Angular Scale 0-360o 0-360o 0-360o 0-360o 0-360o
Angular Scale Accuracy ±0.05o ±0.01°o ±0.01° ±0.01° ±0.01°
International Sugar Scale ±130o Z ±130o Z ±130°Z ±130°Z 130o Z
ISS Accuracy ±0.1°Z ±0.05°Z ±0.05°Z ±0.05°Z ±0.05°Z
Light Sources Integrated Light Integrated Light Integrated Light Integrated Light Integrated Light
Size 27"X13 1/2" 141/2 28"X13 1/2 "14 1/2 28"X13 1/2 " 14 1/2 28"X13 1/2 " 14 1/2 28"X13 1/2 " 14 1/2
Weight 11 kg 12 kg 12 kg 15 kg 15 kg
Note 1: Integrated lighting model does not use sodium lamp.
 
Accessories
  • 10mm/0.1dm, 25mm/0.25dm( both in stainless steel), Centre Filling/Side Filling
  • 50mm/0.5dm , 100mm/1dm, 200mm/2dm, 220mm/2.2dm, 400mm/4dm. Centre Filling/Side Filling
  • Jacketed tubes for precision temperature control of samples are available in 100mm 200mm lengths .
  • Sodium lamp/Tungsten Lamp/High Intensity LED
  • Transformer for sodium lamp model polarimeter
  • Window glasses and washers (Rubber/Neoprene/Ptfe washer)
Note 2: Cold/Hot water circulating baths for sample tube temperature control available as additional accessory
Description

Details

Polarimeter
ADVANCE has been designing and manufacturing precision Polarimeters and Saccharimeters for the last 40 years. This experience ensures the best and latest in Polarimeter technology, designs and features are incorporated in our instruments. Polarimeters are used for the determination of the Optical Rotation of all Optically Active substances and used in testing Pharmaceuticals, Chemicals, Essential Oils, Sugars, Foodstuffs, Brewery products etc.. The Polarimeters and Saccharimeters are available in two series. The PA Series is suitable for observation tubes up to 220mm while PB series can accommodate tubes upto 400 mm. They offer an accuracy of 0.01°Angular Scale and 0.5°ISS.

An outstanding feature of ADVANCE Polarimeters is the incorporation of precision glass scale and scale plate with minutely finished rotating mechanism and Tropic proof highly sensitive optical system. The test result can be read precisely and directly without the aid of a vernier and its associated errors. The latest addition is use of an Integrated Lighting System, in place of the bulky and fragile Sodium Lamp, which gives the advantage of immediate illumination while saving table space and electrical power.
Key Features
The advance optical system of the Polarimeters and Saccharimeters have been designed in order to minimize the destructive influences of a hot and humid climate and abrupt temperature changes on the sensitive optics and are suitable for use in Tropical conditions. Superior quality Optics & highly sensitive Triple Shadow with improved definition offers the advantages such as Permanent focus with difficult and dark liquids High accuracy and repeatability along with strain free viewing
  • Polarimeters and Saccharimeters have been designed in order to minimize the destructive influences of a hot and humid climate and abrupt temperature changes on the sensitive optics and are suitable for use in Tropical conditions.
  • The latest addition is use of an Integrated Lighting System, in place of the bulky and fragile Sodium Lamp, which gives the advantage of immediate illumination while saving table space and electrical power.
  • Superior quality triple shadow system
  • Triple Shadow System rotates with the circle thus affording immediate indication of the direction of the material being examined.
  • Permanent focus with difficult and dark liquids
  • High accuracy and repeatability along with strain free viewing
Technical Specifications*
Instrument Name Polarimeter Polarimeter Polarimeter Polarimeter/Saccharimeter Polarimeter/Saccharimeter
Model No. LSPA-2 LSPA-1R (Standard) LSPA-1R (Deluxe) LSPB-1R / PB-4(Standard) LSPB-1R / PB-4(Deluxe)
Tube Length (Maximum) 220 mm 220 mm 220mm 400mm 400mm
Shadow System Half/Triple Shadow Improved Triple Shadow Improved Triple Shadow & High Improved Triple Shadow Improved Triple Shadow & High
Angular Scale 0-360o 0-360o 0-360o 0-360o 0-360o
Angular Scale Accuracy ±0.05o ±0.01°o ±0.01° ±0.01° ±0.01°
International Sugar Scale ±130o Z ±130o Z ±130°Z ±130°Z 130o Z
ISS Accuracy ±0.1°Z ±0.05°Z ±0.05°Z ±0.05°Z ±0.05°Z
Light Sources Integrated Light Integrated Light Integrated Light Integrated Light Integrated Light
Size 27"X13 1/2" 141/2 28"X13 1/2 "14 1/2 28"X13 1/2 " 14 1/2 28"X13 1/2 " 14 1/2 28"X13 1/2 " 14 1/2
Weight 11 kg 12 kg 12 kg 15 kg 15 kg
Note 1: Integrated lighting model does not use sodium lamp.
 
Accessories
  • 10mm/0.1dm, 25mm/0.25dm( both in stainless steel), Centre Filling/Side Filling
  • 50mm/0.5dm , 100mm/1dm, 200mm/2dm, 220mm/2.2dm, 400mm/4dm. Centre Filling/Side Filling
  • Jacketed tubes for precision temperature control of samples are available in 100mm 200mm lengths .
  • Sodium lamp/Tungsten Lamp/High Intensity LED
  • Transformer for sodium lamp model polarimeter
  • Window glasses and washers (Rubber/Neoprene/Ptfe washer)
Note 2: Cold/Hot water circulating baths for sample tube temperature control available as additional accessory
Additional Information

Additional Information

Code No
Reviews