Automatic Polarimeter / Saccharimeter SAC-i

• FDA 21 CFR Part 11 Software Included in Standard Delivery
• Measurement stability in 12 seconds (4 seconds in the high-speed & consecutive measurement mode)
• Resolution of up to 3 decimal places
• Repeatability of ±0.003° Angle of Rotation and ±0.009°Z
• Up to 999 automatic consecutive measurements followed by average value display
• Sleep & timer feature to take measurement later at specified time
• Improved usability with the use of touch screen technology
• Connectivity to RX Digital Refractometers for automatic purity measurement

This SAC-i has been tested and approved by CONSECANA, the most eminent authority on sugar and ethanol production in the State of São Paulo, Brazil.
 Specifications
Model SAC-i
Measurement Readings Angle of Rotation, International Sugar Scale (without temperature compensation), International Sugar Scale (with Automatic Temperature Compensation), Specific Rotation, Concentration, Purity, and Angle of Rotation (Temperature Compensation of Quartz Plate)
Measurement Range Angle of Rotation -89.9999 to +90.0000° or -360.0000 to +360.0000°
International Sugar Scale -259.0000 to +259.0000°
Resolution Angle of Rotation 0.0001° International Sugar Scale 0.0001°Z
Measurement Accuracy ①Angle of Rotation:
±0.002° (-5.0 to +5.0°)
±0.005° (-45.0 to -5.0°, +5.0 to +45.0°)
②International Sugar Scale:±0.015°Z (-130.0 to +130.0°Z)
Other ranges
①Angle of Rotation:±0.010°
②International Sugar Scale:±0.030°Z
* Checked by reading a standard quartz plate
Repeatability ±0.003° Angle of Rotation and ±0.009°Z
Temperature correction range for ISS 10 to 40℃
Display Panel 7.5 inch color LCD (touch screen)
Light source LED:589nm interference filter
Measurement Wavelength 589nm (equivalent to the sodium-D line spectrum)
Power Supply AC100 to 240V, 50/60Hz
Included Accessories Software, PolariSoft
Observation tube included Observation tubes (100mm(5mL),200mm(10mL))
Dimensions & Weight 60×36.5×21cm, 20.0kg
Output terminals Digital Printer DP-63 or
DP-AD (sold separately), USB flash drive and PC - USB
Description

Details

Automatic Polarimeter / Saccharimeter SAC-i

• FDA 21 CFR Part 11 Software Included in Standard Delivery
• Measurement stability in 12 seconds (4 seconds in the high-speed & consecutive measurement mode)
• Resolution of up to 3 decimal places
• Repeatability of ±0.003° Angle of Rotation and ±0.009°Z
• Up to 999 automatic consecutive measurements followed by average value display
• Sleep & timer feature to take measurement later at specified time
• Improved usability with the use of touch screen technology
• Connectivity to RX Digital Refractometers for automatic purity measurement

This SAC-i has been tested and approved by CONSECANA, the most eminent authority on sugar and ethanol production in the State of São Paulo, Brazil.
 Specifications
Model SAC-i
Measurement Readings Angle of Rotation, International Sugar Scale (without temperature compensation), International Sugar Scale (with Automatic Temperature Compensation), Specific Rotation, Concentration, Purity, and Angle of Rotation (Temperature Compensation of Quartz Plate)
Measurement Range Angle of Rotation -89.9999 to +90.0000° or -360.0000 to +360.0000°
International Sugar Scale -259.0000 to +259.0000°
Resolution Angle of Rotation 0.0001° International Sugar Scale 0.0001°Z
Measurement Accuracy ①Angle of Rotation:
±0.002° (-5.0 to +5.0°)
±0.005° (-45.0 to -5.0°, +5.0 to +45.0°)
②International Sugar Scale:±0.015°Z (-130.0 to +130.0°Z)
Other ranges
①Angle of Rotation:±0.010°
②International Sugar Scale:±0.030°Z
* Checked by reading a standard quartz plate
Repeatability ±0.003° Angle of Rotation and ±0.009°Z
Temperature correction range for ISS 10 to 40℃
Display Panel 7.5 inch color LCD (touch screen)
Light source LED:589nm interference filter
Measurement Wavelength 589nm (equivalent to the sodium-D line spectrum)
Power Supply AC100 to 240V, 50/60Hz
Included Accessories Software, PolariSoft
Observation tube included Observation tubes (100mm(5mL),200mm(10mL))
Dimensions & Weight 60×36.5×21cm, 20.0kg
Output terminals Digital Printer DP-63 or
DP-AD (sold separately), USB flash drive and PC - USB
Additional Information