jainsonsindia partners
 Enquiry Cart

Viscometer

Code:
CAP2000 Viscometer 
  • The CAP2000+ also offers lower shear rates, making it suitable for many applications where small sample volume and good temperature control are necessary.
  • Brookfield's CAP-2000+ offers expanded temperature and viscosity ranges with variable speed capability. The CAP2000+ also offers lower shear rates, making it suitable for many applications where small sample volume and good temperature control are necessary. And the rugged, easy-to-use design make it perfect in environments where other instruments won't last.
 
FEATURES AND BENEFITS
  • Expanded Ranges
  • Viscosity 0.2 - 15,000 Poise
  • Shear Rate 10 - 13,000 sec-1
  • Temperature 5-75°C or 50-235°C
  • Speed of Rotation 5-1000 RPM
  • Meets Industry Standards:  ASTM D4287, ISO 2884 and BS 3900
  • Small sample size, < 1 mL, simplifies testing
  • Integrated temperature control
  • Optional CAPCALC32 software for complete control and data analysis
  • Open system for quick and easy cleaning
What's Included 
Instrument
Choice of Torque Range
            -Standard Torque (ICI Specification) 181,000 dyne· cm
            -Low Torque: 7,970 dyne· cm
Choice of One Cone Spindle
Choice of Temperature Control (L or H)
 
SPECIFICATIONS
MODEL SELECTION: CAP 2000+ Viscometer
Viscosity Range SPEEDS
MODEL Min. Max. RPM Number of Increments
CAP 2000+ See chart below 5-1000 995
 
CAP 2000+ HIGH Torque Cone Viscosity Ranges (Poise) Spindles 01-05
Cone Spindle:Sample Volume ( μ L) : Shear Rate (sec-1): CAP016713.3N CAP023813.3N CAP032413.3N CAP041343.3N CAP05673.3N
CAP 2000+ @ 5-1000 rpm .2-375 .4-750 .8-1.5k 1-3K 3-6k
 
CAP 2000+ LOW Torque Cone Viscosity Ranges (Poise) Spindles 01-05
Low torque is used for applications requiring low shear rates for low/medium viscosity fluids, an optional low torque 797-7,970 dynes•cm instrument can also be ordered.
CAP 2000+ @ 5-1000 rpm .2-16 .2-32 .2-66 .2-130 .2-260
 
CAP 2000+ HIGH Torque Cone Viscosity Ranges (Poise) Spindles 06-10
Cone Spindle:Sample Volume ( μ L) : Shear Rate (sec-1): CAP06303.3N CAP0717002.0N CAP084002.0N CAP091002.0N CAP101705.0N
CAP 2000+ @ 5-1000 rpm 8-15k .78-625* 3.13-2.5k* 12.5-10k* 1-1k*
 
CAP 2000+ LOW Torque Cone Viscosity Ranges (Poise) Spindles 06-10
Low torque is used for applications requiring low shear rates for low/medium viscosity fluids, an optional low torque 797-7,970 dynes•cm instrument can also be ordered.
CAP 2000+ @ 5-1000 rpm .2-660 .2-26 .2-108 .2-440 .2-44
μL = microLiter N = rpm k = 1000 e.g. Cone CAP-01 13.3 x 10 (rpm) = 133 sec-1
* Maximum speed recommended with this spindle is 400 rpm. Viscosity range indicated is for operation at 400 rpm.
Note: Viscosity ranges shown are for illustration; the exact range will depend upon instrument configuration.
Related Accessories 
  • CAP Viscosity Standards
  • Additional Cone Spindle
  • CAPCALC Software
Description

Details

CAP2000 Viscometer 
  • The CAP2000+ also offers lower shear rates, making it suitable for many applications where small sample volume and good temperature control are necessary.
  • Brookfield's CAP-2000+ offers expanded temperature and viscosity ranges with variable speed capability. The CAP2000+ also offers lower shear rates, making it suitable for many applications where small sample volume and good temperature control are necessary. And the rugged, easy-to-use design make it perfect in environments where other instruments won't last.
 
FEATURES AND BENEFITS
  • Expanded Ranges
  • Viscosity 0.2 - 15,000 Poise
  • Shear Rate 10 - 13,000 sec-1
  • Temperature 5-75°C or 50-235°C
  • Speed of Rotation 5-1000 RPM
  • Meets Industry Standards:  ASTM D4287, ISO 2884 and BS 3900
  • Small sample size, < 1 mL, simplifies testing
  • Integrated temperature control
  • Optional CAPCALC32 software for complete control and data analysis
  • Open system for quick and easy cleaning
What's Included 
Instrument
Choice of Torque Range
            -Standard Torque (ICI Specification) 181,000 dyne· cm
            -Low Torque: 7,970 dyne· cm
Choice of One Cone Spindle
Choice of Temperature Control (L or H)
 
SPECIFICATIONS
MODEL SELECTION: CAP 2000+ Viscometer
Viscosity Range SPEEDS
MODEL Min. Max. RPM Number of Increments
CAP 2000+ See chart below 5-1000 995
 
CAP 2000+ HIGH Torque Cone Viscosity Ranges (Poise) Spindles 01-05
Cone Spindle:Sample Volume ( μ L) : Shear Rate (sec-1): CAP016713.3N CAP023813.3N CAP032413.3N CAP041343.3N CAP05673.3N
CAP 2000+ @ 5-1000 rpm .2-375 .4-750 .8-1.5k 1-3K 3-6k
 
CAP 2000+ LOW Torque Cone Viscosity Ranges (Poise) Spindles 01-05
Low torque is used for applications requiring low shear rates for low/medium viscosity fluids, an optional low torque 797-7,970 dynes•cm instrument can also be ordered.
CAP 2000+ @ 5-1000 rpm .2-16 .2-32 .2-66 .2-130 .2-260
 
CAP 2000+ HIGH Torque Cone Viscosity Ranges (Poise) Spindles 06-10
Cone Spindle:Sample Volume ( μ L) : Shear Rate (sec-1): CAP06303.3N CAP0717002.0N CAP084002.0N CAP091002.0N CAP101705.0N
CAP 2000+ @ 5-1000 rpm 8-15k .78-625* 3.13-2.5k* 12.5-10k* 1-1k*
 
CAP 2000+ LOW Torque Cone Viscosity Ranges (Poise) Spindles 06-10
Low torque is used for applications requiring low shear rates for low/medium viscosity fluids, an optional low torque 797-7,970 dynes•cm instrument can also be ordered.
CAP 2000+ @ 5-1000 rpm .2-660 .2-26 .2-108 .2-440 .2-44
μL = microLiter N = rpm k = 1000 e.g. Cone CAP-01 13.3 x 10 (rpm) = 133 sec-1
* Maximum speed recommended with this spindle is 400 rpm. Viscosity range indicated is for operation at 400 rpm.
Note: Viscosity ranges shown are for illustration; the exact range will depend upon instrument configuration.
Related Accessories 
  • CAP Viscosity Standards
  • Additional Cone Spindle
  • CAPCALC Software
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:245 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 245