jainsonsindia partners
 Enquiry Cart

Applicators

Code:

Applicators

Description

Unlike dry cellulose acetate strips that are restricted to low volume micro tests, CellasGEL’s greater thickness allows tests to be performed on semi-micro and macro scales using a wide range of specialist applicators. Consequently greater sample-volumes may be loaded as larger, but finer bands over a wider front. This reduces sample saturation and aids densitometric band quantitation, thereby improving resolution.

Key Features

Unlike dry cellulose acetate strips that are restricted to low volume micro tests, CellasGEL’s greater thickness allows tests to be performed on semi-micro and macro scales using a wide range of specialist applicators.

Technical Specifications:

Code Description Volume applied/sample band width Compatible Strip Size
CSLAPPS22 1 X 2-specimen semi-micro applicator 0.7μl/7mm 2.5 x 14cm
CSLAPPS4P  1 X 4-specimen semi-micro applicator  0.9μl/9mm 5.7 x 14cm
CSLAPPS4  1 X 4-specimen semi-micro applicator  1.2μl/9mm 5.7 x 14cm
CSLAPPS6  1 X 6-specimen semi-micro applicator  0.7μl/7mm 5.7 x 14cm
CSLAPPM8  1 X 8-sample micro applicator  0.3μl/5mm 5.7 x 14cm

 

Ordering Information
 CSLAPPS22 1x 2-specimen semi-micro applicator 0.7μl / 7mm, 2.5x14cm
 CSLAPPS4SP 1x 4-specimen semi-micro applicator 0.9μl / 9mm, 5.7x14cm
 CSLAPPS4 1x 4-specimen semi-micro applicator 1.2μl / 9mm, 5.7x14cm
 CSLAPPS6 1x 6-specimen semi-micro applicator 0.7μl / 7mm, 5.7x14cm
 CSLAPPM8 1x 8-sample micro applicator 0.3μl /5mm, 5.7 x 14cm
Description

Details

Applicators

Description

Unlike dry cellulose acetate strips that are restricted to low volume micro tests, CellasGEL’s greater thickness allows tests to be performed on semi-micro and macro scales using a wide range of specialist applicators. Consequently greater sample-volumes may be loaded as larger, but finer bands over a wider front. This reduces sample saturation and aids densitometric band quantitation, thereby improving resolution.

Key Features

Unlike dry cellulose acetate strips that are restricted to low volume micro tests, CellasGEL’s greater thickness allows tests to be performed on semi-micro and macro scales using a wide range of specialist applicators.

Technical Specifications:

Code Description Volume applied/sample band width Compatible Strip Size
CSLAPPS22 1 X 2-specimen semi-micro applicator 0.7μl/7mm 2.5 x 14cm
CSLAPPS4P  1 X 4-specimen semi-micro applicator  0.9μl/9mm 5.7 x 14cm
CSLAPPS4  1 X 4-specimen semi-micro applicator  1.2μl/9mm 5.7 x 14cm
CSLAPPS6  1 X 6-specimen semi-micro applicator  0.7μl/7mm 5.7 x 14cm
CSLAPPM8  1 X 8-sample micro applicator  0.3μl/5mm 5.7 x 14cm

 

Ordering Information
 CSLAPPS22 1x 2-specimen semi-micro applicator 0.7μl / 7mm, 2.5x14cm
 CSLAPPS4SP 1x 4-specimen semi-micro applicator 0.9μl / 9mm, 5.7x14cm
 CSLAPPS4 1x 4-specimen semi-micro applicator 1.2μl / 9mm, 5.7x14cm
 CSLAPPS6 1x 6-specimen semi-micro applicator 0.7μl / 7mm, 5.7x14cm
 CSLAPPM8 1x 8-sample micro applicator 0.3μl /5mm, 5.7 x 14cm
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:245 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 245