LOSSES DUE TO FRICTION IN PIPE LINES

More Views

LOSSES DUE TO FRICTION IN PIPE LINES

Code:
DESCRIPTION:
The setup consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment.
 
Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch
 
EXPERIMENTATION:
  • To determine the losses due to fiction in pipes.
  • To determine the friction factor for Darcy Weisback equation.
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Electricity 0.5 kW, 220V AC, Single Phase.
  • Floor Area 1.5 x 0.75 m. 
TECHNICAL DETAILS:
Pipe Test Section
(i) Dia ½”, Length: 1m, Material G.I.
(ii) Dia ¾”, Length: 1m, Material G.I.
Water Circulation FHP Pump, Crompton make.
Flow Measurement Using Measuring Tank with Piezometer, Capacity 25 Ltrs
Sump Tank Capacity 50 Ltrs.
Stop Watch Electronic.
Control Panel Comprises of Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHD-005 LOSSES DUE TO FRICTION IN PIPE LINES
 
Description

Details

DESCRIPTION:
The setup consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment.
 
Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch
 
EXPERIMENTATION:
  • To determine the losses due to fiction in pipes.
  • To determine the friction factor for Darcy Weisback equation.
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Electricity 0.5 kW, 220V AC, Single Phase.
  • Floor Area 1.5 x 0.75 m. 
TECHNICAL DETAILS:
Pipe Test Section
(i) Dia ½”, Length: 1m, Material G.I.
(ii) Dia ¾”, Length: 1m, Material G.I.
Water Circulation FHP Pump, Crompton make.
Flow Measurement Using Measuring Tank with Piezometer, Capacity 25 Ltrs
Sump Tank Capacity 50 Ltrs.
Stop Watch Electronic.
Control Panel Comprises of Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 