Details
DESCRIPTION :
The Window Air Conditioning Test Rig unit is required to conduct experiments and demonstrate the process of cooling of atmospheric air. The unit will be fitted with all instruments facilities so that temperature, pressure etc. may be measured at different points in the air conditioning system.
EXPERIMENTATION:
- To study the Vapour Compression air conditioning cycle.
- To Calculate Co-efficient of performance- (COP) by the use of P-H diagram.
UTILITIES REQUIRED :
- Electric supply Single Phase, 220 V AC, 50 Hz., 10 Amp.
- Floor area : 2 m x 1m
TECHNICAL DETAILS:
Compressor |
Hermitically sealed compressor.Capacity 1 Ton, Kirloskar make. |
Condenser |
Air cooled compatible to compressor |
Condenser Cooling fan |
Compatible capacity with permanent lubricated motor. |
Pressure Gauges |
2 Nos. |
Evaporator |
Made of copper tube and aluminumfins fitted with compatible capacity fan. |
Expansion Valve |
Capillary Tube, Compatible Capacity. |
Temperature Sensor |
RTD PT-100 Type. |
TemperatureMeasurement |
Digital Temperature Indicator with multi-channel switch. |
Safety Control |
over load and over current protection for Compressor with Time delay circuit. |
All Other accessories like Hand shut off valves, filter drier and Thermostat, Pressure gauges will be provided. |
An ENGLISH instruction manual will be provided along with the Apparatus |
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
Catalogue No |
Description |
JRAC-004 |
WINDOW AIR CONDITIONING TEST RIG |