jainsonsindia partners
 Enquiry Cart

Heating & Cooling Chambers

Code:
Heating & Cooling Chambers 
-20 to 100 (H flow)
Performance
  • Microprocessor PID control.
  • Temperature calibration / Automatic tuning.
  • Adjustable three-step fan speed with defrosting time and period control.
  • Forced air convection using an optimal cross flow fan for chamber temperature uniformity.
  • Energy efficiency is achieved thanks to optimization of the insulation system. The surface of the unit doesn’t allow high temperatures of over 60℃.
Convenience
  • Two independently controlled chambers merged into a single unit for space saving.
  • Intuitive control panel with bright LED display (0.1℃resolution) and touch-sensitive keypad.
  • Dual wait on/off timer modes. (1 min. to 99 hr. 59 min.)
  • Convenient preset function for 3 most commonly used temperature settings.
  • Up to 9 temperature steps and maximum 200 cycles of repetition programmable for each profile.
  • Built-in cable port to use other instruments inside the chamber. (diameter: 80mm)
  • RS-232 interface for external control and data collection.
Safety
  • Automatic shut off after overheat alarm.
  • Power supply leakage breaker.
  • Over current protection.
  • Open door alarm.
Model LSLCH-11 LSLCH-21 LSLCH-31 LSLCH-11-2C
Chamber volume (L / cu ft) 150/5.3 255/9.0 485/17.1 150/5.3 x 2 chambers
Temperature Range (℃ / ℉) -20 to 100 / -4 to 212
Fluctuation (±℃ / ℉) 1) 0.3 / 0.54
Variation at 80°C (±℃ / ℉) 1) 0.8 / 1.44
Time Heating (min.) 80 (from 20℃ to100℃)
Cooling (min.) 60 (from100℃ to 40℃)
No. of wire shelves (standard / max.) 2 / 12 2 / 24 2 / 29 2 / 12 per chamber
Distance of between shelves (mm / inch) 30 / 1.2
Max. load per shelf (kg / lbs) 15 / 33.1 20 / 44.1 20 / 44.1 15 / 33.1
Permitted total load (kg / lbs) 50 / 110.2 70 / 154.3 70 / 154.3 50 / 110.2 per chamber
Dimension (W×D×H) Interior (mm / inch) 600x500x500/ 23.6x19.7x19.7 600x500x850/ 23.6x19.7x33.5 700x680x1020/ 27.6x26.8x40.2 600x500x500/ 23.6x19.7x19.7
Exterior (mm / inch) 794x1070x1280/ 31.3x42.1x50.4 794x1070x1630/ 31.3x42.1x64.2 894x1250x1800/ 35.2x49.2x70.9 794x1070x1900/ 31.3x42.1x74.8
Net weight (kg / lbs) 125/275.6 185/407.9 225/496.0 195/429.9
Cable Port (mm / inch) Ø 80 / Ø 3.15
Interface port RS-232C
Electrical requirements (230V,60Hz) 6.3A 9.2A 11.1A 12.6A
Electrical requirements (230V,50Hz) 6.6A 9.6A 11.6A 13.2A
 
Description

Details

Heating & Cooling Chambers 
-20 to 100 (H flow)
Performance
  • Microprocessor PID control.
  • Temperature calibration / Automatic tuning.
  • Adjustable three-step fan speed with defrosting time and period control.
  • Forced air convection using an optimal cross flow fan for chamber temperature uniformity.
  • Energy efficiency is achieved thanks to optimization of the insulation system. The surface of the unit doesn’t allow high temperatures of over 60℃.
Convenience
  • Two independently controlled chambers merged into a single unit for space saving.
  • Intuitive control panel with bright LED display (0.1℃resolution) and touch-sensitive keypad.
  • Dual wait on/off timer modes. (1 min. to 99 hr. 59 min.)
  • Convenient preset function for 3 most commonly used temperature settings.
  • Up to 9 temperature steps and maximum 200 cycles of repetition programmable for each profile.
  • Built-in cable port to use other instruments inside the chamber. (diameter: 80mm)
  • RS-232 interface for external control and data collection.
Safety
  • Automatic shut off after overheat alarm.
  • Power supply leakage breaker.
  • Over current protection.
  • Open door alarm.
Model LSLCH-11 LSLCH-21 LSLCH-31 LSLCH-11-2C
Chamber volume (L / cu ft) 150/5.3 255/9.0 485/17.1 150/5.3 x 2 chambers
Temperature Range (℃ / ℉) -20 to 100 / -4 to 212
Fluctuation (±℃ / ℉) 1) 0.3 / 0.54
Variation at 80°C (±℃ / ℉) 1) 0.8 / 1.44
Time Heating (min.) 80 (from 20℃ to100℃)
Cooling (min.) 60 (from100℃ to 40℃)
No. of wire shelves (standard / max.) 2 / 12 2 / 24 2 / 29 2 / 12 per chamber
Distance of between shelves (mm / inch) 30 / 1.2
Max. load per shelf (kg / lbs) 15 / 33.1 20 / 44.1 20 / 44.1 15 / 33.1
Permitted total load (kg / lbs) 50 / 110.2 70 / 154.3 70 / 154.3 50 / 110.2 per chamber
Dimension (W×D×H) Interior (mm / inch) 600x500x500/ 23.6x19.7x19.7 600x500x850/ 23.6x19.7x33.5 700x680x1020/ 27.6x26.8x40.2 600x500x500/ 23.6x19.7x19.7
Exterior (mm / inch) 794x1070x1280/ 31.3x42.1x50.4 794x1070x1630/ 31.3x42.1x64.2 894x1250x1800/ 35.2x49.2x70.9 794x1070x1900/ 31.3x42.1x74.8
Net weight (kg / lbs) 125/275.6 185/407.9 225/496.0 195/429.9
Cable Port (mm / inch) Ø 80 / Ø 3.15
Interface port RS-232C
Electrical requirements (230V,60Hz) 6.3A 9.2A 11.1A 12.6A
Electrical requirements (230V,50Hz) 6.6A 9.6A 11.6A 13.2A
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:245 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 245