Code:
C 7000 Basic Equipment Set 1 Calorimeter
The C 7000 is the first IKA® calorimeter with a completely dry system for measuring the gross calorific value of solid and liquid samples. The temperature is measured directly in the decomposition system. This results in measurement times in the range of 3 to 7 minutes (depending on the sample). The system can manage up to 8 different decomposition vessels using a code ring scheme. 
- High sample frequency 
- Precise and reproducible determination of gross calorific values according to ISO 1928 
- Reduction of routine work through automatic application flow 
- Automatic decomposition vessel identification 
- Interface connections for scale, printer and PC 
- User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data 
- The decomposition vessel can be changed over to use combustible crucibles C 14 
C 7000 basic equipment set 1 consisting of: 
C 7000 Measurement cell 
C 7010 Decomposition vessel, standard 
C 7002 Cooling system 
C 48 Oxygen station 
Model C 7000 Basic Equipment Set 1
Measuring range max. 30000 J
Measuring mode double dry (ISO 1928) yes
Measuring time double dry approx. 3 min
Double dry reproducibility (1g benzoic acid NBS39i) 0.2 %RSD
Working temperature max. 30 °C
Temperature measurement resolution 0.0001 K
Cooling medium temperature min. 12 °C
Cooling medium temperature max. 30 °C
Cooling medium permissible operating pressure 9 bar
Cooling medium tap water
Type of cooling flow
Flow rate min. 120 l/h
Flow rate max. 180 l/h
Oxygen operating pressure max. 40 bar
Interface scale RS232
Interface printer Centronix
Interface PC RS232
Oxygen filling no
Degasification no
Decomposition detection yes
Decomposition vessel C 7010 yes
Dimensions (W x H x D) 310 x 395 x 490 mm
Weight 43 kg
Permissible ambient temperature 18 - 30 °C
Permissible relative humidity 80 %
RS 232 interface yes
Voltage 220 - 240 V
Frequency 50/60 Hz
Power input 260 W
 
Description

Details

C 7000 Basic Equipment Set 1 Calorimeter
The C 7000 is the first IKA® calorimeter with a completely dry system for measuring the gross calorific value of solid and liquid samples. The temperature is measured directly in the decomposition system. This results in measurement times in the range of 3 to 7 minutes (depending on the sample). The system can manage up to 8 different decomposition vessels using a code ring scheme. 
- High sample frequency 
- Precise and reproducible determination of gross calorific values according to ISO 1928 
- Reduction of routine work through automatic application flow 
- Automatic decomposition vessel identification 
- Interface connections for scale, printer and PC 
- User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data 
- The decomposition vessel can be changed over to use combustible crucibles C 14 
C 7000 basic equipment set 1 consisting of: 
C 7000 Measurement cell 
C 7010 Decomposition vessel, standard 
C 7002 Cooling system 
C 48 Oxygen station 
Model C 7000 Basic Equipment Set 1
Measuring range max. 30000 J
Measuring mode double dry (ISO 1928) yes
Measuring time double dry approx. 3 min
Double dry reproducibility (1g benzoic acid NBS39i) 0.2 %RSD
Working temperature max. 30 °C
Temperature measurement resolution 0.0001 K
Cooling medium temperature min. 12 °C
Cooling medium temperature max. 30 °C
Cooling medium permissible operating pressure 9 bar
Cooling medium tap water
Type of cooling flow
Flow rate min. 120 l/h
Flow rate max. 180 l/h
Oxygen operating pressure max. 40 bar
Interface scale RS232
Interface printer Centronix
Interface PC RS232
Oxygen filling no
Degasification no
Decomposition detection yes
Decomposition vessel C 7010 yes
Dimensions (W x H x D) 310 x 395 x 490 mm
Weight 43 kg
Permissible ambient temperature 18 - 30 °C
Permissible relative humidity 80 %
RS 232 interface yes
Voltage 220 - 240 V
Frequency 50/60 Hz
Power input 260 W
 