jainsonsindia partners
 Enquiry Cart

Combustion Calorimeter

Code:
C 200 Combustion Calorimeter
 
C 200-System consists of the following components: 
Measuring cell C 200 
Decomposition vessel C 5010 
Oxygen filling station C 248 
Consumables for calibrations and installation 

Space-saving and low cost combustion calorimeter for determining gross calorific values of liquid and solid samples. 

Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. 

Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses.. 

Manual handling for water and oxygen filling. 

Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks. 

Clear and easily explained display which is simply to use . 

With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage. 

Friendly in aftersales 

Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute. 
All calculations have to be done manually. 
At the other three modes ignition and calculation of the gross calorific value will be done automatically. 
The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually. 

The modes have different measuring times: 
Isoperibolic: approx: 17 min. 
Dynamic : approx. 8 min 
Manual : approx. 17 min 
(depend on the operator) 
Time controlled : 14 min 

The decomposition vessel can be equiped in to use an combustible crucibles C 14 
(accessory C 5010.4 attachment is neessary) 

User-friendly software C 5040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible 
Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory) 
Model C 200
Measuring range max. 40000 J
Measuring mode dynamic 25°C yes
Measuring mode isoperibol 25°C yes
Measuring time dynamic approx. 8 min
Measuring time isoperibol approx. 17 min
Reproducibility dynamic (1g benzoic acid NBS39i) 0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i) 0.1 %RSD
Working temperature max. 25 °C
Temperature measurement resolution 0.0001 K
Interface printer Centronix
Interface PC RS232
Oxygen filling no
Degasification no
Decomposition detection no
Decomposition vessel C 5010 yes
Decomposition vessel C 5012 yes
Analysis according to DIN 51900 yes
Analysis according to ISO 1928 yes
Dimensions (W x H x D) 400 x 400 x 400 mm
Weight 21 kg
Permissible ambient temperature 20 - 25 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
RS 232 interface yes
Voltage 100 - 240 V
Frequency 50/60 Hz
Power input 120 W
 
Description

Details

C 200 Combustion Calorimeter
 
C 200-System consists of the following components: 
Measuring cell C 200 
Decomposition vessel C 5010 
Oxygen filling station C 248 
Consumables for calibrations and installation 

Space-saving and low cost combustion calorimeter for determining gross calorific values of liquid and solid samples. 

Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. 

Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses.. 

Manual handling for water and oxygen filling. 

Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks. 

Clear and easily explained display which is simply to use . 

With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage. 

Friendly in aftersales 

Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute. 
All calculations have to be done manually. 
At the other three modes ignition and calculation of the gross calorific value will be done automatically. 
The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually. 

The modes have different measuring times: 
Isoperibolic: approx: 17 min. 
Dynamic : approx. 8 min 
Manual : approx. 17 min 
(depend on the operator) 
Time controlled : 14 min 

The decomposition vessel can be equiped in to use an combustible crucibles C 14 
(accessory C 5010.4 attachment is neessary) 

User-friendly software C 5040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible 
Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory) 
Model C 200
Measuring range max. 40000 J
Measuring mode dynamic 25°C yes
Measuring mode isoperibol 25°C yes
Measuring time dynamic approx. 8 min
Measuring time isoperibol approx. 17 min
Reproducibility dynamic (1g benzoic acid NBS39i) 0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i) 0.1 %RSD
Working temperature max. 25 °C
Temperature measurement resolution 0.0001 K
Interface printer Centronix
Interface PC RS232
Oxygen filling no
Degasification no
Decomposition detection no
Decomposition vessel C 5010 yes
Decomposition vessel C 5012 yes
Analysis according to DIN 51900 yes
Analysis according to ISO 1928 yes
Dimensions (W x H x D) 400 x 400 x 400 mm
Weight 21 kg
Permissible ambient temperature 20 - 25 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
RS 232 interface yes
Voltage 100 - 240 V
Frequency 50/60 Hz
Power input 120 W
 
Additional Information

Additional Information

Code No
Reviews