jainsonsindia partners
 Enquiry Cart

Heated Bath Circulator

Code:
HBC 10 Basic Heated Bath Circulator
The HBC 10 basic heated bath circulator heats up to a max. temperature of 250 °C. It has a high quality stainless steel bath with a volume of 7.5 – 10.5 liters. The large surface of the radiator allows for an optimum heat exchange and a gentle heating process of the medium. The superior insulation allows for a remarkably fast heat-up time. The easy to clean bath has a front drain valve for safe emptying. In order to drain the system, a hose is connected so there is no direct contact with the tempering fluid. With customer safety as our highest priority, the HBC 10 basic conforms to the highest safety classification III (FL) for use with flammable liquids according to DIN 12876. 
  • Temperature range: 20 - 250 °C
  • Temperature accuracy: ± 0.02 K
  • Integrated cooling coil
  • Adjustable safety circuit
  • Powerful, speed-controlled pressure/suction pump
  • Push and turn buttons for an intuitive menu navigation
  • Large easy to read LED display for pump speed and temperature
  • Visual and acoustic safety warnings
  • USB / RS 232 interface for PC control and documentation using labworldsoft®, as well as updating the device software through our website
Model HBC 10 Basic
Appliance type Circulation thermostat
Class designation acc. DIN 12876 III
Identification according to DIN 12876 FL
Heat output 2500 W
Working temperature min. room temp. +10K @1000rpm °C
Working temperature max. 250 °C
Operating temperature min. (with external cooling) -20 °C
Temperature display yes
Temperature control PT 100
Working temperature sensor PT 100
Safety temperature sensor PT1000
Working temperature display LED
Safety temperature display LED
Temperature stability DIN 12876 0.02 ±K
Connection for ext. temperature sensor PT 100
Display resolution 0.1 K
Display for operation with ext. sensor yes
Set temperature resolution 0.1 ±K
Warning function optical yes
Warning function acoustic yes
Warning function excess temperature yes
Warning function insufficient temperature no
Adjustable safety circuit min. 0 °C
Adjustable safety circuit max. 260 °C
Sub-level protection yes
Over-level protection yes
Filling volume min. 8 l
Filling volume max. 11 l
Pump type Pressure- / suction pump
Pump capacity adjustable yes
Pump pressure max. (0 liters discharge flow) 0.61 bar
Pressure pump (suction side) (0 liter flow) 0.45 bar
Flow rate max. (0 bar back pressure) 31 l/min
Pump connection M16x1
Cooling coil connection NW 8
Bath depth min. 150 mm
Calibration option yes
Technical data complies with the standard DIN 12876
Permissible ON time 100 %
Dimensions (W x H x D) 275 x 456 x 500 mm
Weight 18 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 21
RS 232 interface yes
USB interface yes
Voltage 230 / 100 - 115 V
Frequency 50/60 Hz
Power input 2650 W
 
Description

Details

HBC 10 Basic Heated Bath Circulator
The HBC 10 basic heated bath circulator heats up to a max. temperature of 250 °C. It has a high quality stainless steel bath with a volume of 7.5 – 10.5 liters. The large surface of the radiator allows for an optimum heat exchange and a gentle heating process of the medium. The superior insulation allows for a remarkably fast heat-up time. The easy to clean bath has a front drain valve for safe emptying. In order to drain the system, a hose is connected so there is no direct contact with the tempering fluid. With customer safety as our highest priority, the HBC 10 basic conforms to the highest safety classification III (FL) for use with flammable liquids according to DIN 12876. 
  • Temperature range: 20 - 250 °C
  • Temperature accuracy: ± 0.02 K
  • Integrated cooling coil
  • Adjustable safety circuit
  • Powerful, speed-controlled pressure/suction pump
  • Push and turn buttons for an intuitive menu navigation
  • Large easy to read LED display for pump speed and temperature
  • Visual and acoustic safety warnings
  • USB / RS 232 interface for PC control and documentation using labworldsoft®, as well as updating the device software through our website
Model HBC 10 Basic
Appliance type Circulation thermostat
Class designation acc. DIN 12876 III
Identification according to DIN 12876 FL
Heat output 2500 W
Working temperature min. room temp. +10K @1000rpm °C
Working temperature max. 250 °C
Operating temperature min. (with external cooling) -20 °C
Temperature display yes
Temperature control PT 100
Working temperature sensor PT 100
Safety temperature sensor PT1000
Working temperature display LED
Safety temperature display LED
Temperature stability DIN 12876 0.02 ±K
Connection for ext. temperature sensor PT 100
Display resolution 0.1 K
Display for operation with ext. sensor yes
Set temperature resolution 0.1 ±K
Warning function optical yes
Warning function acoustic yes
Warning function excess temperature yes
Warning function insufficient temperature no
Adjustable safety circuit min. 0 °C
Adjustable safety circuit max. 260 °C
Sub-level protection yes
Over-level protection yes
Filling volume min. 8 l
Filling volume max. 11 l
Pump type Pressure- / suction pump
Pump capacity adjustable yes
Pump pressure max. (0 liters discharge flow) 0.61 bar
Pressure pump (suction side) (0 liter flow) 0.45 bar
Flow rate max. (0 bar back pressure) 31 l/min
Pump connection M16x1
Cooling coil connection NW 8
Bath depth min. 150 mm
Calibration option yes
Technical data complies with the standard DIN 12876
Permissible ON time 100 %
Dimensions (W x H x D) 275 x 456 x 500 mm
Weight 18 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 21
RS 232 interface yes
USB interface yes
Voltage 230 / 100 - 115 V
Frequency 50/60 Hz
Power input 2650 W
 
Additional Information

Additional Information

Code No