Details
Incubated Shakers (Chamber)
Specially designed to be double-stacked on the floor or located on the lab benches for space saving.
Performance
-
Temperature range:
- Ambient +5°C to 80°C for ISS-3075 / 4075.
- Ambient -20°C (Min. 4) to 80°C for ISS-3075R / 4075R.
-
Competitive high shaking speed up to 500 rpm. (Stackable up to 250rpm)
-
Orbital shaking motion in 19.1mm diameter.
-
Three point temperature calibration / Automatic tuning.
-
Microprocessor PID control.
-
Wide speed range even with heavy workload.
- Equipped with a maintenance-free BLDC motor to generate smooth, quiet, uniform, and yet powerful shaking motion.
-
Best effort run function intelligently manages its rpm to keep shaking even workload is out of its capacity.
- Automatic shaking speed adjustment in case of excessive workload such as unbalanced load placement, unusual vibrations caused from unstable floor or external shock.
-
Pleasant test environment by the smooth acceleration and deceleration control.
- Smooth start and smooth stop function prevents chemical spills from flasks or test tubes.
-
High-velocity fan ensures uniform temperature distribution and rapid thermal recovery after door open.
-
Air-tight silicone door seal to provide excellent temperature uniformity.
Convenience
-
Intuitive touch screen LCD controller with easy icons and logical menus.
-
Easy-set digital timer for shaking operation. (1 min. to 999 hr. 59 min.)
-
Wide sample monitoring.
- Clear observation of samples without affecting inner chamber’s environment thanks to the transparent viewing window with bright LED lamps.
-
Repetitive task can be easily performed as the platform stops where it starts.
- Stopping the shaking platform always at the same position is highly beneficial for automated dosing or sampling process.
-
Two adjustable-height shelves provided allow static incubation or refrigeration, which increase storage capacity.
-
Built-in electrical outlet with a safety cover inside the chamber.
-
Corrosion resistance stainless steel interior.
-
Easy-access drain system with a quick disconnect valve offers great convenience to clean up of spills.
-
Built-in RS-232 port and USB port for external control and data collection.
-
Retractable foot caster, beneficial for easy mobility during installation or relocation. (optional)
-
Chambers stackable, up to two levels.
Safety
-
Automatic run after power interruption.
-
Temperature and shaking speed deviation alarm.
-
Over-current protection, Stalled platform check.
-
Triple independent temperature monitor system.
- Temperature deviation alarm (High/Low)
- Electronic temperature limiter (High/Low)
- Mechanical over-temperature limiter (High)
-
Environment-friendly CFC-free refrigerant. (for ISS-3075R / 4075R)
Model |
LSISS-3075 |
LSISS-3075R |
LSISS-4075 |
LSISS-4075R |
Temperature |
Range (℃ / ℉) |
Amb. +5 to 80/ Amb. +9 to 176 |
Amb. -20 (Min. 4) to 80/Amb. -36 (Min. 7.2) to 176 |
Amb. +5 to 80/Amb. +9 to 176 |
Amb. -20 (Min. 4) to 80/Amb. -36 (Min. 7.2) to 176 |
Fluctuation at 37℃ in flask(±℃ / ℉) |
0.1 / 0.18 |
Variation at 37℃ in flask(±℃ / ℉) |
0.5 / 0.90 |
Refrigerator (Hp) |
- |
1/6Hp |
- |
1/6Hp |
Shaking system |
Motion type |
Orbital |
Amplitude size (mm / inch, dia.) |
19.1 / 0.75 |
Speed range (rpm) |
20 to 500 (stackable : 20 to 250) |
Accuracy |
±1% of set speed (>100rpm) / ±1 (≤100rpm) |
Timer |
1 min. to 999 hr 59 min. |
Max. Load (kg / Ibs) |
10 / 22.0 at 500 rpm15 / 33.1 at 400 rpm15 / 33.1 at 250 rpm (stacked) |
10 / 22.0 at 500 rpm21 / 46.3 at 400 rpm21 / 46.3 at 250 rpm (stacked) |
Dimension |
Volume (L / cu ft) |
80 / 2.8 |
150 / 5.3 |
Platform (W×D, mm / inch) |
350×350 / 13.8x13.8 |
450×450 / 17.7×17.7 |
Interior (W×D×H, mm / inch) |
440×440×418 / 17.3×17.3×16.5 |
540×540×518 / 21.3×21.3×20.4 |
Exterior (W×D×H, mm / inch) |
578×815×854 / 22.8x32.1x33.6 |
678×895×934 / 26.7x35.2x36.8 |
Shelves (Standard / Max) |
2 / 8 |
2 / 11 |
Net weight (kg / Ibs) |
153 / 337.3 |
160 / 352.7 |
183 / 403.4 |
190 / 418.9 |
Electrical requirements (230V) |
60Hz, 6.2A |
50Hz, 6.2A |
60Hz, 7.9A |
50Hz, 7.9A |
60Hz, 6.2A |
50Hz, 6.2A |
60Hz, 7.9A |
50Hz, 7.9A |
※ Above specifications can be changed without prior notice.