jainsonsindia partners
 Enquiry Cart

100mA Radiographic X-ray Machine

More Views

100mA Radiographic X-ray Machine

Code:
 
100mA Radiographic X-ray Machine JYSX0101

USE
General radiography, Filter-ray-filter radiograph

Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator

Function
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying

Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling

MAIN TECHNICAL INDEXES
ITEM CONTENTS INDEX
Demand of power supply Capacity Two-phase 30KVA
Voltage Frequency 380V/220V   ±1050HZ ±0.5Hz
Intemal resistance 2Ω(380V)  0.6  Ω(220V)
power supply Adjustable range 380±10% at220V being adjustable continuously
Radiograph Voltage 50-90KV
current Small focus: 15mA,Big focus:30mA 60mA 100mA
time 0.04~6.35s 23grades together grading a according to R10 coefficient
High-voltage generator Capacity 7KVA
Max DC output voltage 90KV
Max DC output current 100mA
X-Ray tube Model 0XD4-2.9/100
Focus Small focus 1.8×1.8mm  big focus4.3×4.3mm
Radiographic Length×width×height of bed surface 2000mm×665mm×700mm
  Moving range of bed surface 640mmin Length,200mm in breadth
table Ray-filter of table Travel in length ≥50mm
Grid density N=28
Convergence distance f.=100cm
Grid ratio r=8
Column of X-ray tube unit Moving Longitudinally along 1000mmor 1800mm
Radiographic table
Distance to friend as moving up and down (along column) 650~1800mm
Rotary around the center of cross arm ±180°
Rotary around the shaft line of X-ray annular tubes  -10°~60°~  +120°
Max size of cassette 356mm×432mm(14×17)
Net  Weight: 600kg  Gross: 695kg  Packing Size: 230*112*111
Description

Details

 
100mA Radiographic X-ray Machine JYSX0101

USE
General radiography, Filter-ray-filter radiograph

Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator

Function
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying

Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling

MAIN TECHNICAL INDEXES
ITEM CONTENTS INDEX
Demand of power supply Capacity Two-phase 30KVA
Voltage Frequency 380V/220V   ±1050HZ ±0.5Hz
Intemal resistance 2Ω(380V)  0.6  Ω(220V)
power supply Adjustable range 380±10% at220V being adjustable continuously
Radiograph Voltage 50-90KV
current Small focus: 15mA,Big focus:30mA 60mA 100mA
time 0.04~6.35s 23grades together grading a according to R10 coefficient
High-voltage generator Capacity 7KVA
Max DC output voltage 90KV
Max DC output current 100mA
X-Ray tube Model 0XD4-2.9/100
Focus Small focus 1.8×1.8mm  big focus4.3×4.3mm
Radiographic Length×width×height of bed surface 2000mm×665mm×700mm
  Moving range of bed surface 640mmin Length,200mm in breadth
table Ray-filter of table Travel in length ≥50mm
Grid density N=28
Convergence distance f.=100cm
Grid ratio r=8
Column of X-ray tube unit Moving Longitudinally along 1000mmor 1800mm
Radiographic table
Distance to friend as moving up and down (along column) 650~1800mm
Rotary around the center of cross arm ±180°
Rotary around the shaft line of X-ray annular tubes  -10°~60°~  +120°
Max size of cassette 356mm×432mm(14×17)
Net  Weight: 600kg  Gross: 695kg  Packing Size: 230*112*111
Additional Information

Additional Information

Code No
Reviews