1. JYSX040-AA Application
Our 4kW portable high frequency x-ray unit is mainly suitable for extremities check, especially for rescues or diagnosis in field operation sites, battlefields, stadiums, vet clinics, etc.

2. JYSX040-AA Features
1) Simple & light structure;
2) 6-segment LED display;
3) Anatomical memories for 24 selection program;
4) Double-loop (analog & digital) high precision control mode;
5) High precision control in tube voltage & current;
6) Self-protection & auto-diagnosis available when malfunction occurs.

3. JYSX040-AA Specifications
Model JYSX040-AA 4KW
Power supply Voltage: AC220V± 10%, 50/60Hz ± 1Hz
Capacity: ≥5kVA;
Internal resistance: ≤0.5Ω
Maximum output power P =110kV×36mA=4kW
Nominal output power 100kV,40mA,0.1s,4kW
Frequency ≥40kHz
kV  adjustable range 40kV~110kV, continuous regulation, stepping 1kV
mA  adjustable range 36mA~70mA
mAs adjustable range 1mAs-200mAs,continuous regulation
Exposure time adjustable range 0.04s~3.2s
X ray tube Focus: 0.6/1.5mm,
Thermal Capacity: 76kHU
Anatomical program 24 memory choices available
Accessories Standard: manual switch, cable
Optional: mobile steel support
 
Description

Details

4kW High frequency portable & mobile vet x-ray unit 

1. JYSX040-AA Application
Our 4kW portable high frequency x-ray unit is mainly suitable for extremities check, especially for rescues or diagnosis in field operation sites, battlefields, stadiums, vet clinics, etc.

2. JYSX040-AA Features
1) Simple & light structure;
2) 6-segment LED display;
3) Anatomical memories for 24 selection program;
4) Double-loop (analog & digital) high precision control mode;
5) High precision control in tube voltage & current;
6) Self-protection & auto-diagnosis available when malfunction occurs.

3. JYSX040-AA Specifications
Model JYSX040-AA 4KW
Power supply Voltage: AC220V± 10%, 50/60Hz ± 1Hz
Capacity: ≥5kVA;
Internal resistance: ≤0.5Ω
Maximum output power P =110kV×36mA=4kW
Nominal output power 100kV,40mA,0.1s,4kW
Frequency ≥40kHz
kV  adjustable range 40kV~110kV, continuous regulation, stepping 1kV
mA  adjustable range 36mA~70mA
mAs adjustable range 1mAs-200mAs,continuous regulation
Exposure time adjustable range 0.04s~3.2s
X ray tube Focus: 0.6/1.5mm,
Thermal Capacity: 76kHU
Anatomical program 24 memory choices available
Accessories Standard: manual switch, cable
Optional: mobile steel support
 