Details
DESCRIPTION:
The set up consists of a column fitted with perforated plates. Liquid is fed at the top of the column through distributor. The solute gas and air are measured separately, mixed in a mixing chamber and then passed through the perforated plates vertically upward and absorbed in liquid. All the flow rates can be independently varied to simulate different conditions. Liquid Sample can be taken out from the bottom of the column for analysis.
EXPERIMENTATION:
- To study absorption of CO2 in aqueous NaOH solution in a sieve plate column.
- To determine the gas phase mass transfer co-efficient, KG a
UTILITIES REQUIRED:
- Compressed Air Supply at 2 Bar, 4 CFM.
- Water Supply
- Floor Drain.
- CO2 cylinder with control valve, pressure regulator and Pressure gauges
- Required Chemicals & Laboratory Glassware.
TECHNICAL DETAILS:
| Column |
Material Stainless Steel.Dia 80mm, Length 1000mm (approx.)One section of column is provided of Borosilicate glass to visualize the process |
| Plates |
Perforated Plates, Material Stainless Steel (7 Nos.) |
| Feed Circulation |
By compressed air. |
| Pressure Regulator |
(0-2) kg/cm². |
| Pressure Gauge |
Bourdon type |
| Feed Tank |
Material Stainless Steel, Capacity 20 Ltrs. |
| Flow measurement |
Rotameters (One each for feed, air & CO2). |
| Collecting Tank |
Material-Stainless Steel, Capacity 10 Ltrs. |
| An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus |
| The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
| Catalogue No |
Description |
| JIMT-021 |
ABSORPTION IN SIEVE PLATE COLUMN |