jainsonsindia partners
 Enquiry Cart

AEROBIC DIGESTER

Code:
DESCRIPTION:
The present set-up consists of a reactor vessel. Liquid and air are fed to the reactor by means of a Peristaltic Feed Pump and a small capacity Compressor, respectively. Flow rate of air can be regulated and controlled with the help of Rotameter. Liquid level can be maintained in the reactor using overflow device connected to the water annular chamber of the vessel. Water is drawn from feed tank to overhead tank with feed pump coupled to DC Motor. A suitable spider-arm dispenser is provided in the bottom of the reactor vessel to distribute the air thoroughly for sufficient bubbling and stirring for reaction. The cylindrical wall of reactor is made from porous material to retain the suspended particles. It can be easily removed for cleaning purpose. Clear water passes through outer annular exit chamber. A heater is provided in the reactor vessel to heat the liquid and its temperature is maintained with provided PID Controller. The reactor lid contains a gas exit pot for sampling the gas for analysis. A Dissolved Oxygen Meter and pH probe accompanies the apparatus, which allows conducting the experiment with ease.

E
XPERIMENTATION:
  1. To study the characteristics of mixed biological reactor.
  2. To study the stochiometry and kinetics of aerobic biological processes. 
UTILITIES REQUIRED:
  • Electricity Supply : 1 Phase, 220 V AC.
  • Water Supply.
  • Table for set-up support. 
TECHNICAL DETAILS:
Reactor Vessel Capacity10 Ltrs
Feed Pump Peristaltic, 24 VDC, 0-30 RPM.
Flow Measurement Rotameter for Air.
Air Diffusers Spider-arm type.
DO Meter Range 0-100% Saturation, Resolution 2%.
Reactor Heater Glass, electrical immersion heater, 200 W
Feed Tank Material SS/PVC, Capacity 30 Ltrs.
Product Tank Material SS/PVC, Capacity 30 Ltrs.
Control Panel comprises of
PID Controller for Heater Standard make.
Temperature Sensor RTD PT-100 Type With standard make On/off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIEBE-002 AEROBIC DIGESTER
 
Description

Details

DESCRIPTION:
The present set-up consists of a reactor vessel. Liquid and air are fed to the reactor by means of a Peristaltic Feed Pump and a small capacity Compressor, respectively. Flow rate of air can be regulated and controlled with the help of Rotameter. Liquid level can be maintained in the reactor using overflow device connected to the water annular chamber of the vessel. Water is drawn from feed tank to overhead tank with feed pump coupled to DC Motor. A suitable spider-arm dispenser is provided in the bottom of the reactor vessel to distribute the air thoroughly for sufficient bubbling and stirring for reaction. The cylindrical wall of reactor is made from porous material to retain the suspended particles. It can be easily removed for cleaning purpose. Clear water passes through outer annular exit chamber. A heater is provided in the reactor vessel to heat the liquid and its temperature is maintained with provided PID Controller. The reactor lid contains a gas exit pot for sampling the gas for analysis. A Dissolved Oxygen Meter and pH probe accompanies the apparatus, which allows conducting the experiment with ease.

E
XPERIMENTATION:
  1. To study the characteristics of mixed biological reactor.
  2. To study the stochiometry and kinetics of aerobic biological processes. 
UTILITIES REQUIRED:
  • Electricity Supply : 1 Phase, 220 V AC.
  • Water Supply.
  • Table for set-up support. 
TECHNICAL DETAILS:
Reactor Vessel Capacity10 Ltrs
Feed Pump Peristaltic, 24 VDC, 0-30 RPM.
Flow Measurement Rotameter for Air.
Air Diffusers Spider-arm type.
DO Meter Range 0-100% Saturation, Resolution 2%.
Reactor Heater Glass, electrical immersion heater, 200 W
Feed Tank Material SS/PVC, Capacity 30 Ltrs.
Product Tank Material SS/PVC, Capacity 30 Ltrs.
Control Panel comprises of
PID Controller for Heater Standard make.
Temperature Sensor RTD PT-100 Type With standard make On/off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIEBE-002 AEROBIC DIGESTER
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282