Autovial Syringeless Filters are preassembled filtration devices for removing particulates from samples. They replace syringe-coupled filtration devices with single, disposable units.

  • Single unit convenience saves time. No assembly required – easier to load.
  • Choice of filter media. Compatible with a wide range of sample types.
  • Ideal for hazardous samples. Self contained device eliminates risk of filter pop-off.
  • Built-in air purge maximizes sample recovery.
  • Sterile option available to maintain sample integrity.
  • Prefilter designed for difficult-to-filter samples (no prefilter in Autovial 5 and in selected Autovial 12).
  • Choice of glass fiber or polypropylene prefilters.

Autovial devices are comprised of two parts: a graduated filter barrel and a plunger. The proven design features an integral filter, built-in air purge, and a support stand that protects the recessed slip-luer tip. They are available in a 5 ml and 12 ml volume capacity.

The Autovial filter is selected according to membrane compatibility with the sample. In practice, the sample is poured into the 5 ml or 12 ml capacity filter barrel. The plunger is inserted into the barrel until the bottom is securely in place; there is a gap of air between the sample and plunger. Then, the tip of the Autovial is placed into the mouth of an autosampler vial or container and the plunger compressed. Filtration begins immediately and, as the plunger is compressed until it reaches the bottom, the membrane is purged with air for maximum sample recovery. For direct instrument injection, a needle is placed on the Autovial slip-luer outlet.

Specifications:

  • Sterility: No
  • Outlet Connector: Male slip luer
  • Housing: Polypropylene (PP)
  • Capacity Max.: 5 ml
  • Sterilization: 121°C for 20 min

Ordering Information:

Cat. No. Description Qty
AV125UCA Autovial Syringeless Filter, Cellulose Acetate, 0.45µm 50/pk
AV125UGMF Autovial Syringeless Filter, Glass Micro Fibre, 0.45µm 50/pk
AV125UNAO Autovial Syringeless Filter, Nylon, 0.45µm 50/pk
AV125UORG Autovial Syringeless Filter, PTFE, 0.45µm 50/pk
AV125UPP Autovial Syringeless Filter, Polypropylene, 0.45µm 50/pk
AV525BGMF Autovial Syringeless Filter, Glass Micro Fibre, 1.0µm 1000/pk
AV525UNAO Autovial Syringeless Filter, Nylon, 0.45µm 1000/pk
AV525UORG Autovial Syringeless Filter, PTFE, 0.45µm 1000/pk
AV115NPEORG Autovial Syringeless Filter, PTFE, 5ml,  0.2µm 50/pk
AV115NPUAQU Autovial Syringeless Filter, PVDF, 5ml,  0.45µm 50/pk
AV115NPUNYL Autovial Syringeless Filter, Nylon, 5ml,  0.45µm 50/pk
AV115NPUORG Autovial Syringeless Filter, PTFE, 5ml,  0.45µm 50/pk
AV115UGMF Autovial Syringeless Filter, Glass Micro Fibre, 5ml,  0.45µm 50/pk
AV125EAQU Autovial Syringeless Filter, PVDF, 12ml,  0.2µm 50/pk
AV125ENAO Autovial Syringeless Filter, Nylon , 12ml,  0.2µm 50/pk
AV125EORG Autovial Syringeless Filter, PTFE, 12ml,  0.2µm 50/pk
AV125EPP Autovial Syringeless Filter, Polypropylene, 12ml,  0.2µm 50/pk
AV125NPUAQU Autovial Syringeless Filter, PVDF with no prefilter, 12ml,  0.45µm 50/pk
AV125NPUPSU Autovial Syringeless Filter, Polysulphone with no prefilter, 12ml,  0.45µm 50/pk
AV125SAQU Autovial Syringeless Filter, PVDF, 12ml, sterile  0.2µm 40/pk
AV125SNAO Autovial Syringeless Filter, Nylon, 12ml, sterile  0.2µm 40/pk
AV125SORG Autovial Syringeless Filter, PTFE, 12ml, sterile  0.2µm 40/pk
AV125UAQU Autovial Syringeless Filter, PVDF, 12ml,  0.45µm 50/pk

 

Description

Details

Autovial Syringeless Filter

Autovial Syringeless Filters are preassembled filtration devices for removing particulates from samples. They replace syringe-coupled filtration devices with single, disposable units.

  • Single unit convenience saves time. No assembly required – easier to load.
  • Choice of filter media. Compatible with a wide range of sample types.
  • Ideal for hazardous samples. Self contained device eliminates risk of filter pop-off.
  • Built-in air purge maximizes sample recovery.
  • Sterile option available to maintain sample integrity.
  • Prefilter designed for difficult-to-filter samples (no prefilter in Autovial 5 and in selected Autovial 12).
  • Choice of glass fiber or polypropylene prefilters.

Autovial devices are comprised of two parts: a graduated filter barrel and a plunger. The proven design features an integral filter, built-in air purge, and a support stand that protects the recessed slip-luer tip. They are available in a 5 ml and 12 ml volume capacity.

The Autovial filter is selected according to membrane compatibility with the sample. In practice, the sample is poured into the 5 ml or 12 ml capacity filter barrel. The plunger is inserted into the barrel until the bottom is securely in place; there is a gap of air between the sample and plunger. Then, the tip of the Autovial is placed into the mouth of an autosampler vial or container and the plunger compressed. Filtration begins immediately and, as the plunger is compressed until it reaches the bottom, the membrane is purged with air for maximum sample recovery. For direct instrument injection, a needle is placed on the Autovial slip-luer outlet.

Specifications:

  • Sterility: No
  • Outlet Connector: Male slip luer
  • Housing: Polypropylene (PP)
  • Capacity Max.: 5 ml
  • Sterilization: 121°C for 20 min

Ordering Information:

Cat. No. Description Qty
AV125UCA Autovial Syringeless Filter, Cellulose Acetate, 0.45µm 50/pk
AV125UGMF Autovial Syringeless Filter, Glass Micro Fibre, 0.45µm 50/pk
AV125UNAO Autovial Syringeless Filter, Nylon, 0.45µm 50/pk
AV125UORG Autovial Syringeless Filter, PTFE, 0.45µm 50/pk
AV125UPP Autovial Syringeless Filter, Polypropylene, 0.45µm 50/pk
AV525BGMF Autovial Syringeless Filter, Glass Micro Fibre, 1.0µm 1000/pk
AV525UNAO Autovial Syringeless Filter, Nylon, 0.45µm 1000/pk
AV525UORG Autovial Syringeless Filter, PTFE, 0.45µm 1000/pk
AV115NPEORG Autovial Syringeless Filter, PTFE, 5ml,  0.2µm 50/pk
AV115NPUAQU Autovial Syringeless Filter, PVDF, 5ml,  0.45µm 50/pk
AV115NPUNYL Autovial Syringeless Filter, Nylon, 5ml,  0.45µm 50/pk
AV115NPUORG Autovial Syringeless Filter, PTFE, 5ml,  0.45µm 50/pk
AV115UGMF Autovial Syringeless Filter, Glass Micro Fibre, 5ml,  0.45µm 50/pk
AV125EAQU Autovial Syringeless Filter, PVDF, 12ml,  0.2µm 50/pk
AV125ENAO Autovial Syringeless Filter, Nylon , 12ml,  0.2µm 50/pk
AV125EORG Autovial Syringeless Filter, PTFE, 12ml,  0.2µm 50/pk
AV125EPP Autovial Syringeless Filter, Polypropylene, 12ml,  0.2µm 50/pk
AV125NPUAQU Autovial Syringeless Filter, PVDF with no prefilter, 12ml,  0.45µm 50/pk
AV125NPUPSU Autovial Syringeless Filter, Polysulphone with no prefilter, 12ml,  0.45µm 50/pk
AV125SAQU Autovial Syringeless Filter, PVDF, 12ml, sterile  0.2µm 40/pk
AV125SNAO Autovial Syringeless Filter, Nylon, 12ml, sterile  0.2µm 40/pk
AV125SORG Autovial Syringeless Filter, PTFE, 12ml, sterile  0.2µm 40/pk
AV125UAQU Autovial Syringeless Filter, PVDF, 12ml,  0.45µm 50/pk

 

Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282