Details
DESCRIPTION:
This equipment comprises of a Axial Flow Fan coupled to a AC Motor. A Pitot Tube is provided in the delivery line of Axial fan for static, dynamic and differential pressure measurement.
EXPERIMENTATION:
- To find out the discharge, head and efficiency of the Axial Fan
- To plot the graph Efficiency Vs Discharge
- To plot the graph Discharge Vs Head
UTILITIES REQUIRED:
- Electricity Supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth connection.
- Floor Area required: 3 m x 0.75 m.
TECHNICAL DETAILS:
| Axial Fan |
Compatible Capacity. |
| Drive |
1 HP motor. |
Pitot Tube
(with manometer)
|
For Static, Dynamic and Differential Pressure measurement.
|
| Stop watch |
Electronic |
| Control Panel Comprises of |
| Energy measurement |
Electronic Energy meter, L&T make. |
| MCB |
For overload protection. |
| Standard make On/Off Switch, Mains Indicator, etc. |
| An ENGLISH instruction manual consisting of experimental procedures, block diagram etc.will be provided along with the Apparatus. |
| The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
| Catalogue No. |
Description |
| JIHD-154 |
AXIAL FAN TEST RIG (Fixed Speed with AC Motor) |