APPLICATIONS

  • 100 % air exhaust
  • Negative pressure air surrounding all biological contaminated parts
  • Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
  • There is no recirculation withing the work area.
  • Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
  • Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
  • Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
  • 100% of the air is pulled into the facility exhaust system for appropriate treatment.
  • Type B2 cabinet are hard-connected to an exhaust system.
  • Negative pressure surrounds the work area with double wall plenums for protection.
  • Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters MAIN/SUPPLY FILTER having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger. The highly efficient HEPA filter maintains the optimum cleanliness and purity. Being equipped with the prefilter, it can extend the life of HEPA filter.
  • Aerodynamic airflow grills maintain safety and prevents blockage.
  • U.V and fluorescent interlock available
  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
  • Sash is counterbalanced for smooth and light weight operation with standard opening for easier access to work zone and enhanced user safety.
  • CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.

Class-II Biosafety Cabinet Protection :

  • Personnel protection from harmful agents used inside the biosafety cabinet.
  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.
  • Environmental protection from contaminants contained within the biosafety cabinet.

Class-II Biosafety Cabinet Key Features :

  • A front access opening with carefully maintained inward air flow.
  • HEPA-filtered, vertical, unidirectional airflow within the work area.
  • HEPA-filtered exhaust air to the room or exaust to a facility exhaust system.

Class-II Biosafety Cabinet Applications :

  • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
  • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
  • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However for level 4 Class III cabinets are recommended.

Class - II

Protection From Particulates

From Vapors and Gases

Type B2

Personnel, Work Area (Product) and Environment

Offer protection to personnel (offer protection to environment if exhausted to treated system.          

Exhaust System With Blower

  • With an integral and essential exhaust system consisting of a heavy duty and powerful motor blower system, Class II Type B2 biological safety cabinet is able to exhaust 100% potentially contaminated air outside the cabinet & air.

Drain Trough With Valve

  • The trough at base is easy to clean and for offloading liquid spillage if any.

Upper & Front Cover

  • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

Decontamination By Uv Lamp

  • UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.

Front Window/Sash

  • Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.

Splash Proof Electric Supply Socket

  • Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.

Material Of Construction

  • Internal Working Chamber is made up of Stainless Steel (SS-304).
  • External Cabinet is fabricated of Cold Rolled Steel Duly powder Coated.

Front Airflow Intake Grid

  • Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.

Floor Stand And Castor Wheels

  • Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

Technical Specifications:

  • MOC: Internal Working Chamber- Stainless steel (SS-304), Exterior Cabinet- Cold Rolled Steel Duly Powder Coated or Stainless Steel (SS-304)
  • Pre – Filter: Mounted on aluminum frame, of rating 20 microns
  • Supply / Main Filter: HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10
  • Exhaust Filter: HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10
  • Electrical Socket: Electrical Socket is provided for using small electrical devices
  • Power Supply: 220/230 Volts AC supply
  • Heavy Duty Exhaust System: Standard fitted to the system for 100% exhaust
  • Exhaust Tunnel/Duct (Option): Available on per running feet basis
  • Sash Lift: Can be lifted and adjusted manually

Ordering Information:

Cat. No.

Dimension (W x D x H) mm

LI-12300/1

Biological Safety Cabinet, Type B2, 600 x 600 x 600 mm

LI-12300/2

Biological Safety Cabinet, Type B2, 900 x 600 x 600 mm

LI-12300/3

Biological Safety Cabinet, Type B2, 1200 x 600 x 600 mm

LI-12300/4

Biological Safety Cabinet, Type B2, 1500 x 600 x 600 mm

LI-12300/5

Biological Safety Cabinet, Type B2, 1780 x 600 x 600 mm

 

Option:

 

Cat. No.

Options

LI-12301/1

 ULPA Filter in lieu of HEPA filter

LI-12301/2

 Front door made of Toughened Glass (Tempered) in lieu of plexi glass

LI-12301/3

 Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer)

LI-12301/4

 Electronic filter choke alarm (Differential Pressure Monitor)

LI-12301/5

Microprocessor Controller with door position alarm with Auto Switch off mode for motor

blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of

sterilizing time of the chamber and the switches off U.V. germicidal tune and automatically

switches ON the fluorescent light, alerting the user that the bench is ready for use.

LI-12301/6

 Gas Burner

LI-12301/7

 Glove ports with gloves

LI-12301/8

 Exhaust ducting per running feet

LI-12301/9

 Digital down flow velocity indicator

 

 

Description

Details

BIOLOGICAL SAFETY CABINET (TYPE B-2)-164 B2

APPLICATIONS

  • 100 % air exhaust
  • Negative pressure air surrounding all biological contaminated parts
  • Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
  • There is no recirculation withing the work area.
  • Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
  • Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
  • Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
  • 100% of the air is pulled into the facility exhaust system for appropriate treatment.
  • Type B2 cabinet are hard-connected to an exhaust system.
  • Negative pressure surrounds the work area with double wall plenums for protection.
  • Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters MAIN/SUPPLY FILTER having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger. The highly efficient HEPA filter maintains the optimum cleanliness and purity. Being equipped with the prefilter, it can extend the life of HEPA filter.
  • Aerodynamic airflow grills maintain safety and prevents blockage.
  • U.V and fluorescent interlock available
  • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
  • Sash is counterbalanced for smooth and light weight operation with standard opening for easier access to work zone and enhanced user safety.
  • CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.

Class-II Biosafety Cabinet Protection :

  • Personnel protection from harmful agents used inside the biosafety cabinet.
  • Product protection to avoid contamination of the works, experiment or process from outside contaminants.
  • Environmental protection from contaminants contained within the biosafety cabinet.

Class-II Biosafety Cabinet Key Features :

  • A front access opening with carefully maintained inward air flow.
  • HEPA-filtered, vertical, unidirectional airflow within the work area.
  • HEPA-filtered exhaust air to the room or exaust to a facility exhaust system.

Class-II Biosafety Cabinet Applications :

  • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
  • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
  • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However for level 4 Class III cabinets are recommended.

Class - II

Protection From Particulates

From Vapors and Gases

Type B2

Personnel, Work Area (Product) and Environment

Offer protection to personnel (offer protection to environment if exhausted to treated system.          

Exhaust System With Blower

  • With an integral and essential exhaust system consisting of a heavy duty and powerful motor blower system, Class II Type B2 biological safety cabinet is able to exhaust 100% potentially contaminated air outside the cabinet & air.

Drain Trough With Valve

  • The trough at base is easy to clean and for offloading liquid spillage if any.

Upper & Front Cover

  • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

Decontamination By Uv Lamp

  • UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.

Front Window/Sash

  • Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.

Splash Proof Electric Supply Socket

  • Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.

Material Of Construction

  • Internal Working Chamber is made up of Stainless Steel (SS-304).
  • External Cabinet is fabricated of Cold Rolled Steel Duly powder Coated.

Front Airflow Intake Grid

  • Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.

Floor Stand And Castor Wheels

  • Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

Technical Specifications:

  • MOC: Internal Working Chamber- Stainless steel (SS-304), Exterior Cabinet- Cold Rolled Steel Duly Powder Coated or Stainless Steel (SS-304)
  • Pre – Filter: Mounted on aluminum frame, of rating 20 microns
  • Supply / Main Filter: HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10
  • Exhaust Filter: HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10
  • Electrical Socket: Electrical Socket is provided for using small electrical devices
  • Power Supply: 220/230 Volts AC supply
  • Heavy Duty Exhaust System: Standard fitted to the system for 100% exhaust
  • Exhaust Tunnel/Duct (Option): Available on per running feet basis
  • Sash Lift: Can be lifted and adjusted manually

Ordering Information:

Cat. No.

Dimension (W x D x H) mm

LI-12300/1

Biological Safety Cabinet, Type B2, 600 x 600 x 600 mm

LI-12300/2

Biological Safety Cabinet, Type B2, 900 x 600 x 600 mm

LI-12300/3

Biological Safety Cabinet, Type B2, 1200 x 600 x 600 mm

LI-12300/4

Biological Safety Cabinet, Type B2, 1500 x 600 x 600 mm

LI-12300/5

Biological Safety Cabinet, Type B2, 1780 x 600 x 600 mm

 

Option:

 

Cat. No.

Options

LI-12301/1

 ULPA Filter in lieu of HEPA filter

LI-12301/2

 Front door made of Toughened Glass (Tempered) in lieu of plexi glass

LI-12301/3

 Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer)

LI-12301/4

 Electronic filter choke alarm (Differential Pressure Monitor)

LI-12301/5

Microprocessor Controller with door position alarm with Auto Switch off mode for motor

blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of

sterilizing time of the chamber and the switches off U.V. germicidal tune and automatically

switches ON the fluorescent light, alerting the user that the bench is ready for use.

LI-12301/6

 Gas Burner

LI-12301/7

 Glove ports with gloves

LI-12301/8

 Exhaust ducting per running feet

LI-12301/9

 Digital down flow velocity indicator

 

 

Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282