jainsonsindia partners
 Enquiry Cart

Chemistry Analyzer

Code:
Chemistry Analyzer 
  • Advanced  and unique optical system, ray filter or grating optical splitting system,
  • freedom to define the testing items
  • Initiated voice prompt function
  • Original double reagent testing system
  • Original counting measurement function
  • Built-in optional reagent parameter ,can be delete, revise, and store
  • Real-time reveals the press curve, ,manual or automatic measurement mode,
  • Input emergency free
  • Independent control testing system ,long-time total controllers’ results
Main Technical Specification
Model MBPS-520
Analysis method End-point, fixed-time(two point rate) kinetics, non-linear, calibration, dual-wave length, double reagent, immune-turbidimetry
Wave length range 300-800nm
Optical system Optical splitting system
Wave length 8 standard filters, 340, 380, 405,492, 510, 546, 578, 620nm
Wave length accuracy ±2nm,  band width‹12nm
Flow cell 32μl quartz flow cell, optical path: 10mm
Suction amount 1-3000μl ,recommend >300μl
Light source: Tungsten-halogen lamp
Absorbency range -0.214-3500Abs
Temperature 37℃ ,30℃,25℃(room), temperature accuracy:±0.1℃
Cross  contamination  ‹1%
Repeatability ‹1%
Control function L-J, X, SD, CV%
 Power supply 220±22VAC, 50 ±1HZ  100W
Size : 380mm(L)*320mm(W)*150mm(H)
Working environment: Temperature 0-40℃
Humidity 10-90%
Weight 8kg
 
Description

Details

Chemistry Analyzer 
  • Advanced  and unique optical system, ray filter or grating optical splitting system,
  • freedom to define the testing items
  • Initiated voice prompt function
  • Original double reagent testing system
  • Original counting measurement function
  • Built-in optional reagent parameter ,can be delete, revise, and store
  • Real-time reveals the press curve, ,manual or automatic measurement mode,
  • Input emergency free
  • Independent control testing system ,long-time total controllers’ results
Main Technical Specification
Model MBPS-520
Analysis method End-point, fixed-time(two point rate) kinetics, non-linear, calibration, dual-wave length, double reagent, immune-turbidimetry
Wave length range 300-800nm
Optical system Optical splitting system
Wave length 8 standard filters, 340, 380, 405,492, 510, 546, 578, 620nm
Wave length accuracy ±2nm,  band width‹12nm
Flow cell 32μl quartz flow cell, optical path: 10mm
Suction amount 1-3000μl ,recommend >300μl
Light source: Tungsten-halogen lamp
Absorbency range -0.214-3500Abs
Temperature 37℃ ,30℃,25℃(room), temperature accuracy:±0.1℃
Cross  contamination  ‹1%
Repeatability ‹1%
Control function L-J, X, SD, CV%
 Power supply 220±22VAC, 50 ±1HZ  100W
Size : 380mm(L)*320mm(W)*150mm(H)
Working environment: Temperature 0-40℃
Humidity 10-90%
Weight 8kg
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282