COMBINED FLOW REACTOR

Code:
DESCRIPTION:
CRE Lab- homogeneous
This set-up is used to study a non-catalytic homogeneous second order liquid phase reaction under ambient condition in a combined reactor. It consists of two reactors connected in series, one is plug flow reactor and another mixed flow reactor.
In an ideal Plug Flow Reactor (PFTR) there is no mixing in the direction of flow and complete mixing perpendicular to direction of flow. Concentration of reactants varies along the length of reactor but not in radial direction. In case of a coil turbulence is introduced due to frequent change in direction of flow and presence of secondary flow, so a higher value of reaction rate constant is expected in coil tube type plug flow reactor.
In an ideal MFR (i.e. an ideal steady state flow reactor) the contents in reactor are well mixed and have uniform composition throughout. Thus the exit stream has the same composition as the fluid within the reactor.

The set up consists of two feed tanks through which two reactants are fed to the reactors fitted in series. Rotameters are provided to measure the individual flow of Chemicals. The flow rate can be adjusted by operating the needle valves provided on respective Rotameter. The compressed air is used for circulation of feed. 1st is a helical coil tube type reactor made up of SS pipe. Reactants enter at lower end coming out of the top of coil from where it is fed to a MFR fitted with stirrer for proper mixing. Samples are collected for analysis. Pressure Regulator, Pressure Gauge and Safety Valve are fitted in the compressed air line.

The same setup can be used as individual Plug Flow Reactor (Coil Tube type) and Mixed Flow Reactor

EXPERIMENTATION:
  • Sponification Reaction Study in a Combined Reactor
  • Sponification Reaction Study in Coil Tube Type Plug Flow Reactor
  • Sponification Reaction Study in a MFR.
  • To determine Reaction Rate Constant.
UTILITIES REQUIRED: 
  • Compressed Air Supply at 2 Bar, 0.5 CFM.
  • Water Supply
  • Floor Drain
  • Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted.
TECHNICAL DETAILS:
1st Reactor Material Stainless Steel, Capacity (0.6-0.7) Ltrs. (approx) (Helical Coiled Tube Type)
2nd Reactor Material Stainless Steel, Capacity 2 Ltrs (Approx).
Stirrer for MFR Stainless Steel Impeller and shaft coupled with FHP motor
Feed Tank (2Nos.) Material Stainless Steel, Capacity - 20 Ltrs.
 Feed Circulation  By compressed air.
Flow Measurement Rotameter 2 Nos. (one each for Reactants).
Piping Stainless Steel and PVC
Pressure Regulator 0-2 Kg/cm2
Pressure Gauge  Bourdon type 0-2 Kg/cm2
Stop Watch Electronic.
Control Panel 
comprising of
Standard make on/off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No. Description
JICRE-011A COMBINED FLOW REACTOR(Compressed Air Feed System)
 
Description

Details

DESCRIPTION:
CRE Lab- homogeneous
This set-up is used to study a non-catalytic homogeneous second order liquid phase reaction under ambient condition in a combined reactor. It consists of two reactors connected in series, one is plug flow reactor and another mixed flow reactor.
In an ideal Plug Flow Reactor (PFTR) there is no mixing in the direction of flow and complete mixing perpendicular to direction of flow. Concentration of reactants varies along the length of reactor but not in radial direction. In case of a coil turbulence is introduced due to frequent change in direction of flow and presence of secondary flow, so a higher value of reaction rate constant is expected in coil tube type plug flow reactor.
In an ideal MFR (i.e. an ideal steady state flow reactor) the contents in reactor are well mixed and have uniform composition throughout. Thus the exit stream has the same composition as the fluid within the reactor.

The set up consists of two feed tanks through which two reactants are fed to the reactors fitted in series. Rotameters are provided to measure the individual flow of Chemicals. The flow rate can be adjusted by operating the needle valves provided on respective Rotameter. The compressed air is used for circulation of feed. 1st is a helical coil tube type reactor made up of SS pipe. Reactants enter at lower end coming out of the top of coil from where it is fed to a MFR fitted with stirrer for proper mixing. Samples are collected for analysis. Pressure Regulator, Pressure Gauge and Safety Valve are fitted in the compressed air line.

The same setup can be used as individual Plug Flow Reactor (Coil Tube type) and Mixed Flow Reactor

EXPERIMENTATION:
  • Sponification Reaction Study in a Combined Reactor
  • Sponification Reaction Study in Coil Tube Type Plug Flow Reactor
  • Sponification Reaction Study in a MFR.
  • To determine Reaction Rate Constant.
UTILITIES REQUIRED: 
  • Compressed Air Supply at 2 Bar, 0.5 CFM.
  • Water Supply
  • Floor Drain
  • Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted.
TECHNICAL DETAILS:
1st Reactor Material Stainless Steel, Capacity (0.6-0.7) Ltrs. (approx) (Helical Coiled Tube Type)
2nd Reactor Material Stainless Steel, Capacity 2 Ltrs (Approx).
Stirrer for MFR Stainless Steel Impeller and shaft coupled with FHP motor
Feed Tank (2Nos.) Material Stainless Steel, Capacity - 20 Ltrs.
 Feed Circulation  By compressed air.
Flow Measurement Rotameter 2 Nos. (one each for Reactants).
Piping Stainless Steel and PVC
Pressure Regulator 0-2 Kg/cm2
Pressure Gauge  Bourdon type 0-2 Kg/cm2
Stop Watch Electronic.
Control Panel 
comprising of
Standard make on/off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No. Description
JICRE-011A COMBINED FLOW REACTOR(Compressed Air Feed System)
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282