jainsonsindia partners
 Enquiry Cart

Decomposition System

Code:
AOD 1 Decomposition system
Description : 
The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially unorganic samples under pressure in a closed system 
The system consists of: 
AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) 
- Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg 
- Absorption of the combustion products in an aqueous medium 
- Catalytic support of the oxidation process with auto-regenerating catalytic insidewalls of the decomposition vessel 
- Pressure vessel of high-grade stainless steel 
- Decomposition temperature up to 1200 °C 
- Max. operating pressure during decomposition 195 bar 
- Decomposition time < 3 min 
- The decomposition vessel can be changed over to use combustible crucibles C 14 
- Control standards for Cl, S ( AOD 1.11) , F and Br ( AOD 1.12 accessory ) 
- Introduction of the combustion gases into the absorption solution via venting station C 7030 

The principal and function is based on the method of the combustion in the bomb calorimeter and validated according 
DIN 51577, part 1 dt. 1982 
other relevants validations are: 
- DIN / EN 14582, determination characteristics of waste, halogene and sulfur content 
- DIN 51527 , Testing of solid samples, determination for the clorine content 
Technical Data : 
Model AOD 1
Decomposition time 3 min
Core temperature max. 1200 °C
Pressure max. 195 bar
Chamber volume 210 ml
Oxygen operating pressure max. 40 bar
Dimensions (W x H x D) 400 x 480 x 260 mm
Weight 10 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
Voltage 230 V
Frequency 50/60 Hz
Power input 45 W
 
Description

Details

AOD 1 Decomposition system
Description : 
The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially unorganic samples under pressure in a closed system 
The system consists of: 
AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) 
- Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg 
- Absorption of the combustion products in an aqueous medium 
- Catalytic support of the oxidation process with auto-regenerating catalytic insidewalls of the decomposition vessel 
- Pressure vessel of high-grade stainless steel 
- Decomposition temperature up to 1200 °C 
- Max. operating pressure during decomposition 195 bar 
- Decomposition time < 3 min 
- The decomposition vessel can be changed over to use combustible crucibles C 14 
- Control standards for Cl, S ( AOD 1.11) , F and Br ( AOD 1.12 accessory ) 
- Introduction of the combustion gases into the absorption solution via venting station C 7030 

The principal and function is based on the method of the combustion in the bomb calorimeter and validated according 
DIN 51577, part 1 dt. 1982 
other relevants validations are: 
- DIN / EN 14582, determination characteristics of waste, halogene and sulfur content 
- DIN 51527 , Testing of solid samples, determination for the clorine content 
Technical Data : 
Model AOD 1
Decomposition time 3 min
Core temperature max. 1200 °C
Pressure max. 195 bar
Chamber volume 210 ml
Oxygen operating pressure max. 40 bar
Dimensions (W x H x D) 400 x 480 x 260 mm
Weight 10 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
Voltage 230 V
Frequency 50/60 Hz
Power input 45 W
 
Additional Information

Additional Information

Code No
Reviews