jainsonsindia partners
 Enquiry Cart

ELECTROLUX - VAPOUR ABSORPTION REFRIGERATION TEST RIG

ELECTROLUX - VAPOUR ABSORPTION REFRIGERATION TEST RIG

Code:
DESCRIPTION :
The set up demonstrates the students about the basic principal of a vapour absorption refrigeration cycle. The test rig is designed for the study of thermodynamics of vapour absorption refrigeration cycle by measuring temperature at different position.
 
 EXPERIMENTATION:
  •  To Calculate Co-efficient of performance. 
UTILITIES REQUIRED :
  • Electric Supply : Single Phase, 220 V AC, 50 Hz, 5-15 Amp. combined socket with earth connection.
  • Bench Area : 1.5 m x 1m
  • Computer System : Pentium IV with DVD Drive, Windows XP, MS-Office XP version pre-loaded.
  • One USB slot required in PC for DATA ACQUISITION CARD. 
TECHNICAL DETAILS:
Sealed Circuit The System has no moving parts at all, which makes it Silent and very durable.
Refrigerant Mixture of three fluid system Ammonia(NH3) + Water (H2O) + Hydrogen (H2)
Gases Non – CEC, Non – HCFC, Non – FCKW, Non – Freon
Mode of System Externally heated by electric resistance Temperature
Evaporator Coil Type evaporator with facility to determine performance efficiency ratio (PER)
Volume of Cabinet 41 Ltrs., Voltage Input – 65 Watts,Electrical Consumption/24 Hrs. – 0.8 kWh, Auto Defrost Fuzzy Logic System,Voltage – Single Phase, 220 Volts, AC 50 Hz.
Temperature Sensor RTD PT-100 Type
Control Panel comprises of
Digital Voltmeter 0-300 V
Temperature Measurement Digital Temperature Indicator withmulti-channel switch.
An ENGLISH instruction manual will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JRAC-009 ELECTROLUX - VAPOUR ABSORPTIONREFRIGERATION TEST RIG
 
 
 
Description

Details

DESCRIPTION :
The set up demonstrates the students about the basic principal of a vapour absorption refrigeration cycle. The test rig is designed for the study of thermodynamics of vapour absorption refrigeration cycle by measuring temperature at different position.
 
 EXPERIMENTATION:
  •  To Calculate Co-efficient of performance. 
UTILITIES REQUIRED :
  • Electric Supply : Single Phase, 220 V AC, 50 Hz, 5-15 Amp. combined socket with earth connection.
  • Bench Area : 1.5 m x 1m
  • Computer System : Pentium IV with DVD Drive, Windows XP, MS-Office XP version pre-loaded.
  • One USB slot required in PC for DATA ACQUISITION CARD. 
TECHNICAL DETAILS:
Sealed Circuit The System has no moving parts at all, which makes it Silent and very durable.
Refrigerant Mixture of three fluid system Ammonia(NH3) + Water (H2O) + Hydrogen (H2)
Gases Non – CEC, Non – HCFC, Non – FCKW, Non – Freon
Mode of System Externally heated by electric resistance Temperature
Evaporator Coil Type evaporator with facility to determine performance efficiency ratio (PER)
Volume of Cabinet 41 Ltrs., Voltage Input – 65 Watts,Electrical Consumption/24 Hrs. – 0.8 kWh, Auto Defrost Fuzzy Logic System,Voltage – Single Phase, 220 Volts, AC 50 Hz.
Temperature Sensor RTD PT-100 Type
Control Panel comprises of
Digital Voltmeter 0-300 V
Temperature Measurement Digital Temperature Indicator withmulti-channel switch.
An ENGLISH instruction manual will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JRAC-009 ELECTROLUX - VAPOUR ABSORPTIONREFRIGERATION TEST RIG
 
 
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282