- Description
-
Details
Germinator With Temperature & Rh And Alternator Type
General Requirements :
- Seed Germinator is designed to work successfully in every climatic condition.
- Seed Germinator is suitable to be tested with all the kind of substrata (Top of paper, between paper, Sands and glass plates).
- Higher humidity levels can be maintained & humidity will be displayed.
- It has provision to Programmed/different temperatures, light levels for different time intervals to simulate customer’s equirements for normal seedling germination.
- Have facility to record data and storage.
- Have Programme lock, Have Audio Visual Alarm
Specifications :
- No. of Chamber : One (heating & cooling)
- Capacity : 432 liter
- Display : Digital LCD display
- Number of shelves : '12-15
- Temperature range : 5- 45°C
- Temperature resolution : 0.1°C
- Temp. selection resolution : 0.1°C
- Temperature accuracy : ± 0.2°C
- Temperature stability : ± 0.5°C
- Air circulation : 1 Fan (minimum)
- Temperature uniformity : ± 0.7°C
- Relative Humidity range : 100%
- Relative Humidity resolution : 1%
- Relative Humidity selection resolution : 1%
- Relative Humidity accuracy : ± 3%
- Relative Humidity stability : ± 3%
- Light intensity : Intensity is adjustable up to 160-170 µmol/m2 sec
- Working environment : 10 – 40°C
- External Dimension(mm) (W x B x H) : 815 x 750 x 2150 (approx.)
- Power supply : 220-240 VAC/1Ph/50 Hz
Cabinet Construction : Interior and exterior wall feature a stainless steel design. Overall wall thickness is 55-60 mm with environmentally friendly (CFC free). Door opening provides full access to the chamber interior. A magnetic gasket provides a tight seal to door frame. A second internal glass door provides observation window without disturbing the internal atmosphere. Shelving tiers of white epoxy coated aluminum.
Refrigeration : Cooling for seed germinators is provided by a self-contained air-cooled condensing unit with hot gas bypass for continuous compressor operation.
Humidification : System is a centrifugal humidifier. Centrifugal atomizing humidifiers supplied with clean water.
Control system : Control system is a programmable Base system, with color LCD touch screen, capable of programming temperature, humidity and light intensity. PID controlled base system, Relative humidity sensor is an electronic psychrometer with wet sock. The controlling system converts the difference between wet and dry bulb reading.
Ordering Information:
Cat. No. Description JAW-STZ008 Germinator With Temperature & Rh And Alternator Type - Additional Information
-