H2O2 Gas Plasma Sterilizer
We are designing and manufacturing range of hydrogen peroxide (h2o2) low temperature plasma sterilizermachines that can be economically purchased by all around hospitals. Using the trusted technology and enhanced capabilities, these systems are used to sterilize various medical instruments such as surgical endoscope and other accessories. Even long, narrow lumens can be effectively sterilized! These Plasma sterilizers feature advanced technology for safe low-temperature sterilization that uses hydrogen peroxide as sterilization agent with plasma technology inside chamber with homogeneous Plasma distribution.
we have been trying to fulfil customers' satisfaction through the means of distinguished features with easy-to-use and strong sterilization efficacy that can be differentiated from conventional product. Central Sterilization Departments and O.R.'s will appreciate the rapid turnaround time and cost-effective, validated, sterilization of moisture and / or heat sensitive devices.
Features:
Can be easily installed and relocate |
User friendly chamber design |
No special facilities required (Water / vent) |
Easy to clean and maintain |
Rapid cycle time |
Corrosion & Acid proof housing |
Optimize utilization of instrument inventory |
Easy to use sterilization agent cassette |
Processes a wide range of surgical instrument |
High vacuum pump for deep penetration |
Compatible with moisture / heat-sensitive materials |
Thermal printer for complete cycle information |
Environment friendly design |
Spare parts available in stock |
No aeration after sterilization |
Caster wheels for easy relocation |
Specifications
Models |
JBST-PLWS40 |
JBST-PLWS80 |
JBST-PLWS150 |
Chamber Volume |
Actual: 44 Litres Usable: 40 Litres |
Actual: 80 Litres Usable: 71 Litres |
Actual: 156 Litres Usable: 126 Litres |
Construction |
Stainless Steel 316 / 316L |
Processing Temperature |
Below 55°C |
Control System |
Microprocessor |
Display |
Touch Screen |
Printer |
Thermal Printer |
Touch Screen Functions |
Phase Temperature Date and time Cycle Selected Set point follow up Option for manual interaction |
Data Storage |
Memory Card |
Total Cycle Time |
Around 45 Minutes |
Noise |
< 60 db |
Door |
One / Two |
Alarm |
Door Lock Power Failure Low / High Temp. range Vacuum & Pressure |
Peripheral Devices |
Biological Incubator |
Power Consumption |
2.5 KVA |
Power Supply |
230 / 110 V, Single Phase 50/60 Hz |
Mobility |
4 Wheels |
Standards |
NP EN ISO 9001:2000, EN ISO 13485:2003 EN ISO 14937, EN 61010-2-040, EN 61010-2-042 |
Construction:
Only high grade stainless steel material ; SS 316 stainless steel is used for chamber including internal shelving, jacket and door to guarantee high performance and durability of the pressure vessel. The frames, external panels, valves and piping are also manufactured by stainless steel. The chamber is designed to withstand pressure from absolute vacuum up to +3.5 bars.
Door Options:
These machines are provided by either one or two doors as an option.
Monitoring and Control:
Equipped with microprocessor based control system, which features simple operation of the units; furthermore, these also offer effective monitoring and control. These systems come with:
-
Easy to read touch screen
-
User-friendly interface indicating cycle stage and elapsed time
-
Biological and chemical indicators housed in vials are used in routine control
Safety Features:
These units ensure safety for all the users, patients and the environment. Safety features include:
-
No hazardous or odorous emissions
-
Low temperature and pressure during sterilization
-
The sterilization process results in water and oxygen by-products
-
Door is locked during cycle operation
Validation:
These plasma sterilizer systems are able to perform independent validation according to the ISO 14937 with an optional validation kit. Each phase of the cycle is validated. The validation kit includes Temperature and pressure sensors and PC software.
Lumen Guidelines:
Validated for stainless steel lumens with 1 mm diameter and 50 cm in length, and soft lumens with 1 mm diameter and 10 meters in length.
Standards and Directives:
Developed according to the following international standards and directives:
Standards
NP EN ISO 9001:2000, EN ISO 13485:2003, EN ISO 14937, EN 61010-2-040, EN 61010-2-042
Directives
73/23/EEC, 89/336/EEC, 98/37/EEC, 93/42/EEC, CE Medical Device Mark 0344
-
H202 agent (6 x 80ml)
-
H202 agent (6 x 140 ml)
-
Printer paper (5 rolls per box)
-
Biological Indicator (30 per case)
-
Incubator
-
Chemical Indicator Strip (250 per pack)
-
Chemical Indicator Tape (5 rolls per box)
-
Smart Card reader
Our company is your one stop source for high quality plasma Sterilizers designed and developed to meet stringent quality standards and are supplied to all over India, Asia, Africa and Middle East countries. We are pleased to get you in contact by sending us email or by phone. Choose from our standard models or send us your unique specifications, we will quote you with highly reasonable price. We promise to offer you highly personalized service.