Details
DESCRIPTION:
The apparatus consists of fabricated shell, inside which coil tubes on outer side are fitted. The present set up is a heat exchanger, with cold water flows through shell. Valves are provided to control the flow rates of hot and cold water. Flow rates of hot and cold water are measured using Rotameters. A magnetic drive pump is used to circulate the hot water from a re-cycled type water tank, which is fitted with heaters and Digital Temperature Controller.
The present set-up has a facility to interface the system with computer which enables to log the experimental data using computer. The educational software and data-logging package has been developed for unit. The software environment base is of Labview of NATIONAL INSTRUMENTS,USA. This software is compatible to interfacing unit designed by "Lab Smith". This software package provides a comprehensive educational software environment within which the investigations can be performed. This software is capable to tabulate the sample readings according to the requirement of experiment under study and results obtained can be compared. The real time data acquisition can be done by interfacing the set-up with computer using software. Software allows the user to have control on data logging, printing the stored data, preparing spread sheets in Excel etc.
EXPERIMENTATION:
The main object of the experimental setup is to study the following at various flow rates:
- LMTD
- Heat transfer rate
- Overall Heat Transfer Co-efficient.
UTILITIES REQUIRED :
- Water supply 20 lit/min (approx.) and drain.
- Electricity Supply : 1 Phase, 220 V AC, 4 kW.
- Floor area of 1.5 m x 0.75 m.
- Computer System: Pentium IV with DVD Drive, Windows 7, MS-Office pre-loaded. One USB slot required in PC for DATA ACQUISITION CARD.
TECHNICAL DETAILS :
System |
Water to Water. |
Shell |
Material Stainless steel. Insulated with ceramic wool and cladded with aluminum foil.Dia. 220 mm, Length 500 mm |
Tube |
OD 16mm approx., Coil Type |
Water Flow Measurement |
By flow sensor (2Nos.) one each for cold & hot fluid. |
Hot Water Tank |
Made of Stainless steel Insulated with ceramic fibre wool. |
Hot Water Circulation |
Magnetic Pump |
Heaters |
Nichrome wire heater (2 Nos.) |
Temperature measurement |
By temperature transmitter, RTD PT-100 type. |
Control panel comprising of |
Temperature Controller |
PID Controller, 0-199.9°C, (For Hot Water Tank) |
With standard make on/off switch, Mains Indicator etc. |
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus |
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
Catalogue No |
Description |
JIHT-516 |
HELICAL COIL HEAT EXCHANGER(With Data Logging Facility) |