The Hanna Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The Checker® is both accurate and affordable.

Compact, Portable Design

Built-in Timer

One-Button Operation

Details

The HI720 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure calcium. Designed as a more accurate alternative to chemical test kits, the HI720 provides quick, accurate results in four easy steps:

Features at-a-glance

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Water quality, Environmental, Plating, Education

Specifications

Range 0.00 - 2.70 ppm
Resolution 0.01 ppm
Accuracy @ 25°C/77°F ±5% of reading ± 0.20 ppm
Light Source LED @ 525 nm
Light Detector silicon photocell
Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method. The reaction between calcium and reagents causes a reddish-violet tint in the sample.
Environment 0 to 50oC (32 to 122oF); RH max 95% non-condensing
Battery Type (1) 1.5V AAA
Auto-off after ten minutes of non-use
Dimensions 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”)
Weight 64 g (2.25 oz.)
Ordering Information HI720 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual

 

Description

Details

HI720 - Calcium Hardness Checker® HC

The Hanna Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The Checker® is both accurate and affordable.

Compact, Portable Design

Built-in Timer

One-Button Operation

Details

The HI720 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure calcium. Designed as a more accurate alternative to chemical test kits, the HI720 provides quick, accurate results in four easy steps:

Features at-a-glance

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Water quality, Environmental, Plating, Education

Specifications

Range 0.00 - 2.70 ppm
Resolution 0.01 ppm
Accuracy @ 25°C/77°F ±5% of reading ± 0.20 ppm
Light Source LED @ 525 nm
Light Detector silicon photocell
Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method. The reaction between calcium and reagents causes a reddish-violet tint in the sample.
Environment 0 to 50oC (32 to 122oF); RH max 95% non-condensing
Battery Type (1) 1.5V AAA
Auto-off after ten minutes of non-use
Dimensions 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”)
Weight 64 g (2.25 oz.)
Ordering Information HI720 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual

 

Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282