LOSSES DUE TO FRICTION IN PIPE LINES (With Data Logging Facility)

More Views

LOSSES DUE TO FRICTION IN PIPE LINES (With Data Logging Facility)

Code:
DESCRIPTION:
The setup consists of 2 pipes of different diameters, which are connected in parallel. To measure the pressure losses, pressure sensors are provided Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured by flow sensor.
 
The present set-up has a facility to interface the system with computer which enables to log the experimental data using computer. The educational software and data-logging package has been developed for unit. The software environment base is of Lab view of NATIONAL INSTRUMENTS, USA. This software is compatible to interfacing unit designed by “Lab Smith”. This software package provides a comprehensive educational software environment within which the investigations can be performed. This software is capable to tabulate the sample readings according to the requirement of experiment under study and results obtained can be compared. The real time data acquisition can be done by interfacing the set-up with computer using software. Software allows the user to have control on data logging, printing the stored data, preparing spread sheets in Excel etc.
 
EXPERIMENTATION:
  • To determine the losses due to fiction in pipes.
  • To determine the friction factor for Darcy Weisbach equation.
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Electricity 0.5 kW, 220V AC, Single Phase.
  • Floor Area 1.5 x 0.75 m.
  • Computer System: Pentium IV with DVD Drive, Windows 7, MS-Office pre-loaded. One USB slot required in PC for DATA ACQUISITION CARD.
TECHNICAL DETAILS:
Pipe Test Section
(i) Dia ½”, Length: 1m, Material G.I.
(ii) Dia ¾”, Length: 1m, Material G.I.
Water Circulation FHP Pump, Crompton make.
Flow Measurement By Using Flow Sensor
Sump Tank Capacity 50 Ltrs.
Pressure Measurement By Using Pressure Sensor
Control Panel Comprises of Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHD-505
LOSSES DUE TO FRICTION IN PIPE LINES
(With Data Logging Facility)
 
Description

Details

DESCRIPTION:
The setup consists of 2 pipes of different diameters, which are connected in parallel. To measure the pressure losses, pressure sensors are provided Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured by flow sensor.
 
The present set-up has a facility to interface the system with computer which enables to log the experimental data using computer. The educational software and data-logging package has been developed for unit. The software environment base is of Lab view of NATIONAL INSTRUMENTS, USA. This software is compatible to interfacing unit designed by “Lab Smith”. This software package provides a comprehensive educational software environment within which the investigations can be performed. This software is capable to tabulate the sample readings according to the requirement of experiment under study and results obtained can be compared. The real time data acquisition can be done by interfacing the set-up with computer using software. Software allows the user to have control on data logging, printing the stored data, preparing spread sheets in Excel etc.
 
EXPERIMENTATION:
  • To determine the losses due to fiction in pipes.
  • To determine the friction factor for Darcy Weisbach equation.
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Electricity 0.5 kW, 220V AC, Single Phase.
  • Floor Area 1.5 x 0.75 m.
  • Computer System: Pentium IV with DVD Drive, Windows 7, MS-Office pre-loaded. One USB slot required in PC for DATA ACQUISITION CARD.
TECHNICAL DETAILS:
Pipe Test Section
(i) Dia ½”, Length: 1m, Material G.I.
(ii) Dia ¾”, Length: 1m, Material G.I.
Water Circulation FHP Pump, Crompton make.
Flow Measurement By Using Flow Sensor
Sump Tank Capacity 50 Ltrs.
Pressure Measurement By Using Pressure Sensor
Control Panel Comprises of Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHD-505
LOSSES DUE TO FRICTION IN PIPE LINES
(With Data Logging Facility)
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282