The Nellcor™ Portable SpO2 Patient Monitoring System, PM10N, is a convenient, handheld monitor that is ideal for spot-checks or continuous monitoring in various healthcare and home use settings. 
Product Details:
Usage Hospital, Clinic
Model JNT1BV

Specifications:
Enclosure
Weight 274 g (0.604 lbs), including four batteries
Dimensions 70 mm W x 156 mm H x 32 mm D
(2.76 in W x 6.14 in H x 1.26 in D)
Display
Screen size 88.9 mm (3.5 in), measured diagonally
Screen type TFT LCD, white LED backlight, viewing cone of 60º and optimal viewing distance of 1 meter
Resolution 320 x 480 pixels
Alarms
Categories Patient status and system status
Priorities Low, medium and high
Notification Audible and visual
Setting Default, institutional and last setting
Alarm volume level 49 to 89 dB
Alarm system delay <10s
Range and Accuracy
Range Type Range Values
Measurement Ranges  
SpO2 saturation range 1% to 100%
Pulse rate range 20 to 250 beats per minute (bpm)
Perfusion range 0.03% to 20%
Display sweep speed 6.25 mm/sec
Measurement Accuracy
Saturation
Adult 70% to 100% ±2 digits
Adult and neonate low sat 60 to 80% ±3 digits
Neonate 70 to 100% ±2 digits
Low perfusion 70 to 100% ±2 digits
Adult and neonate with motion 70 to 100% ±3 digits
 
Description

Details

Nellcor Handheld Pulse Oximeter

The Nellcor™ Portable SpO2 Patient Monitoring System, PM10N, is a convenient, handheld monitor that is ideal for spot-checks or continuous monitoring in various healthcare and home use settings. 
Product Details:
Usage Hospital, Clinic
Model JNT1BV

Specifications:
Enclosure
Weight 274 g (0.604 lbs), including four batteries
Dimensions 70 mm W x 156 mm H x 32 mm D
(2.76 in W x 6.14 in H x 1.26 in D)
Display
Screen size 88.9 mm (3.5 in), measured diagonally
Screen type TFT LCD, white LED backlight, viewing cone of 60º and optimal viewing distance of 1 meter
Resolution 320 x 480 pixels
Alarms
Categories Patient status and system status
Priorities Low, medium and high
Notification Audible and visual
Setting Default, institutional and last setting
Alarm volume level 49 to 89 dB
Alarm system delay <10s
Range and Accuracy
Range Type Range Values
Measurement Ranges  
SpO2 saturation range 1% to 100%
Pulse rate range 20 to 250 beats per minute (bpm)
Perfusion range 0.03% to 20%
Display sweep speed 6.25 mm/sec
Measurement Accuracy
Saturation
Adult 70% to 100% ±2 digits
Adult and neonate low sat 60 to 80% ±3 digits
Neonate 70 to 100% ±2 digits
Low perfusion 70 to 100% ±2 digits
Adult and neonate with motion 70 to 100% ±3 digits
 