Details
Plant Growth Chambers
Ample capacity, maximum capacity of 1000L to satisfy user's plant growth needs
Performance
General control system
-
5℃to 50℃(lamp off) / 10℃to 50℃. (lamp on)
-
Max. to 35,000Lux for GC-1000.
Max. to 20,000Lux for GC-300 Models.
-
40 to 80% RH for GC-300TLH. (at 20 to 35℃)
50 to 90% RH for GC-1000TLH. (at 20 to 35℃)
-
Max. 5,000ppm CO2 on/off system. (optional)
-
Microprocessor PID control / Temperature calibration / Automatic tuning.
-
10 step programmable temperature, humidity, and illumination profiles and repeatable steps of up to 999 cycles.
Illuminance control system
-
Uniformed luminescence distribution.
-
Broad distribution of side lamps for hastening the growth of plants.
-
High intensity illumination of upper lamp for light efficient and low thermal load. (for GC-1000TLH/1000TL)
-
Unique construction for minimization of heat increase from surrounding lamps.
- Tempered glass door blocks heated air from lamps.
- Designed to exhaust heated air through upper vent holes. (for GC-1000TLH)
-
Stable and long lasting lighting through introduction of high frequency electronic ballast lamps.
Convenience
-
Ergonomically designed door construction.
- Inner glass door with silicone and external door with magnetic sealing for dual airtight packing.
- Well designed providing a smooth open for minimization of damage to plants.
-
Wide inner tempered glass door for clear observation of plant growth without affecting inner chamber’s environment.
-
Tall plants can be grown inside of the chamber with adjustment of shelve level.
-
Maintenance of water supply are easily performed with a front water tank. (GC-1000TLH)
- Water level check indicated by water level bar in the tank.
-
Water supply during operation is also available for long term test purposes.
-
Adjustable water tank position. (for GC-300TLH)
-
Detachable condenser air-filter for easy maintenance of refrigerating efficiency.
- Maintenance of air filter no longer cumbersome with our detachable condenser air filter.
-
Casters for easy mobility during installation or relocation.
-
Eco-friendly CFC-free refrigerant use.
Safety
-
Automatic shut off after overheat alarm.
-
Low and empty water level alarm.
-
Power supply leakage breaker.
-
Over current protection,
-
Open door alarm.
Lamps setting
Model |
LSGC-300TL |
LSGC-300TLH |
LSGC-1000TLH |
Chamber volume (L / cu ft) |
300 / 10.6 |
1000 / 35.3 |
Control system |
Microprocessor PID controller |
Temperature |
Range (℃ / ℉) |
5 to 50 / 41 to 122 - Lamp off |
10 to 50 / 50 to 122 - Lamp on |
20 to 50 / 68 to 122 - with humidity |
Fluctuation (±℃ / ℉) at 25℃ |
0.1 / 0.18 - without humidity |
Variation (±℃ / ℉) at 25℃ |
0.8 / 1.43 - without humidity |
Illumination |
Range (Lux) |
0 to 20,000 |
0 to 35,000 |
Control (steps) |
10 |
11 |
Lamp |
Fl lamp (32W×18ea) |
FL lamp (32W×16ea) |
Metal lamp (400W×3ea) |
Humidity |
Range (% RH) |
- |
40 to 80 at 20 to 35℃ |
50 to 90 at 20 to 35℃ |
70 to 90 at 36 to 50℃ |
60 to 90 at 36 to 50℃ |
Fluctuation (±RH) at 60% RH |
- |
3 |
Co2(optional) |
Range (ppm) |
Max. 5,000 |
Sensor |
NDIR CO2 sensor |
Refrigerant (HP) |
1/2 |
3/4 |
Temp. heater power (W) |
750×2ea |
1,500×2ea |
Humid. heater power (W) |
- |
1300 |
1500 |
Dimension (W×D×H) |
Interior (mm / inch) |
510×540×1100 / 20×21.3×43.3 |
1200×800×1080 / 47.2×31.5×42.5 |
Exterior (mm / inch) |
700×805×1900 / 27.6×30.1×74.8 |
1410×1070×2150 / 55.5×42.1×84.7 |
Net weight (kg / lbs) |
250 / 551.2 |
550 / 1212.5 |
Electrical requirements (230V) |
60Hz / 12.5A |
50Hz / 12.5A |
60Hz / 16A |
50Hz / 16A |
60Hz / 30A |