Details
DESCRIPTION:
Plate type heat exchanger consists of frame in which independent metal plates are clamped between a head and follower. The plates are sealed at their outer edges and around the ports by gaskets, which are so arranged that the liquid and the heating/cooling media are directed alternately into passages formed between the plates. The hot fluid enters at the top on the right side of the fixed end cover and flows downwards through alternate channels between the plates. The Hot fluid leaves the exchanger through a connection at the bottom of the fixed end cover. The cold fluid enters at the bottom of the left side of the fixed end cover. The cold fluid flows in counter current flow through alternate channels between the plates and leaves the exchanger at the top on the left side of the fixed end cover.
EXPERIMENTATION:
To calculate : -
- LMTD
- Heat transfer rate
- Overall Heat Transfer Co-efficient.
UTILITIES REQUIRED:
- Electricity Supply: 1 Phase, 220 V AC, 5 KW.
- Water Supply at constant head (10 LPM Approx.)
- Floor Drain
- Floor area of 1.75 m x 1m.
TECHNICAL DETAILS :
| System |
Water to Water |
| Plates |
Material Stainless Steel |
| Frame |
Rigid MS Structure |
| Water Flow Measurement |
By Rotameter (2Nos.) one each for cold & hot fluid. |
| Hot Water Tank |
Made of Stainless steel, Double Wall, Insulated with ceramic |
| Hot Water Circulation |
Magnetic Pump |
| Heaters |
Nichrome wire heater |
| Control panel comprising of |
| Digital Temp. Controller |
0-199.9°C, (For Hot Water Tank) |
| Digital Temp. Indicator |
0-199.9°C, with multi-channel switch |
| Temperature Sensors |
RTD PT-100 type.-4Nos. |
| With standard make on/off switch, Mains Indicator etc. |
| An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus |
| The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
| Catalogue No |
Description |
| JIHT-014 |
PLATE TYPE HEAT EXCHANGER |