Fatscan Milk Analyzer
- Fatscan™ is a hand held Milk Analyzer for simple use at the Dairy Farms/Dairies/Milk Collection Centers. It provides fast and accurate determination of the Fat & SNF contents in raw milk. The measurement principle is related from the NIR reflection - spectrometry.
- fatscan™ measures the characteristics of milk most accurately. It is based on the advanced and trusted NIR technology approved for the Food & Pharma Industry worldwide. It can serve for a much longer duration as compared to the present range of milk analyzers. It does not require technical maintenance.
Features:
-
Low After Sale expenses
-
Based on an innovative NIR Technology
-
Low expense for maintenance and service
-
High Accuracy
-
Easy to operate
-
No Moving Mechanical parts
-
PC Data Capturing Software
-
Self-diagnostics
FATSCAN 5005 P/T
UHT MILK / PROCESSED MILK (Pasteurized and Homogenized)
FAT% :- Measuring Range: 1.50% - 5.0%
COW MILK / PROCESSED MILK (Pasteurized and Homogenized)
FAT% :- MEASURING RANGE: 1.5% - 6.0%
FATSCAN 5005 P/T+
UHT MILK / PROCESSED MILK (Pasteurized and Homogenized)
FAT % :- MEASURING RANGE(1.50% - 5.0%)
COW MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(1.5% - 6.0%)
BUFFALO MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(6.0% - 13.50%)
SNF% :- MEASURING RANGE(7.0% - 10.0%)
FATSCAN 5005 Pro P/T
COW MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(1.50% - 6.0%)
BUFFALO Milk (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(6.0% - 13.5%)
MIXED Milk (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(2.0% - 13.50%)
SNF% :- MEASURING RANGE(7.0% - 10.0%)
FATSCAN 5005 P/T++
UHT MILK / PROCESSED MILK (Pasteurized and Homogenized)
FAT% :- MEASURING RANGE(1.50% - 5.0%)
SKIM MILK (Pasteurized and Homogenized)
FAT% :- MEASURING RANGE(0.05% - 0.8%)
COW MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(1.5% - 6.0%)
BUFFALO MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(6.0% - 13.50%)
MIXED MILK (Unhomogeneous) Raw Milk
FAT% :- MEASURING RANGE(2.0% - 13.50%)
SNF% :- MEASURING RANGE(7.0% - 10.C)
Technical Specification:
Working principle |
NIR absorbance by reflection measurement |
Testing time |
About 28 sec |
Sample volume |
20ml |
Sample temperature |
35-40 degree calcius |
Accuracy |
± 0.10% FAT & ±0.20%SNF in UHT/ processed/ cow/ buffalo milk± 0.15% FAT & 0.20% SNF in mixed milk |
Repeatability |
± 0.5 % FAT & ±0.8%SNF in UHT/ processed/ cow/ buffalo milk± 0.8% FAT & 0.8% SNF in mixed milk |
Storage |
On board ram up to 255 results |
USB port |
Available for data transfer to a computer |
R232 serial port |
Available for data transfer to a computer and a protocol printer |
Warranty |
One year |