- Description
-
Details
LabSmith510 Benchtop Conductivity/TDS Meter
High performance laboratory conductivity meter with TDS measurement mode, 1 to 3 points calibration, system menu contains 7 optional parameters. Accuracy: 1% F.S.
Features:
• High performance laboratory conductivity meter is suitable for routine measurements.
• 1 to 3 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), temperature coefficient and TDS conversion factor.
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration improves the measurement accuracy of meter.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Help message as a operational guide that helps user quickly begin using the meter.
• System menu allows setting the 7 parameters, including the number of calibration points, temperature unit, hold function, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
Applictaions:
• Water and wastewater treatment
• Research and educations
• Environmental monitoring and aquaculture
• Printing and chemical industryOrdering Information with Technical Specifications:
Catalogue No. LabSmith510 Conductivity Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm Accuracy ±1% F.S Resolution 0.01, 0.1, 1 Calibration Points 1 to 3 points Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm TDS Range 0~100ppt (Max. 200ppt, depending on factor setting) Accuracy ±1% F.S TDS Factor 0.1~1.0 (Default 0.5) Temperature Range 0~105°C, 32~221°F Accuracy ±1°C Resolution 0.1°C Calibration Range Measured value ±10°C Temperature Units °C or °F Others Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic Temperature Coefficient 0.0~10.0%/°C Cell Constant K=0.1, 1, 10 or User-defined Normalization Temperature 25°C Hold Function Manual or Automatic Power Off Manual or Automatic (180 minutes after last key pressed) Reset Function Yes Connector 6-pin Mini Plug Display LCD (135×75mm) Power Requirements DC9V, using AC adapters, 220VAC/50Hz Dimensions 210(L)×205(W)×75(H)mm Weight 1.5kg Accessories:
Catalogue No. Accessories LabSmith510-S CON-1 Conductivity Electrode TP-10K Temperature Probe Conductivity Standard Solutions (84µS, 1413µS, 12.88mS) DC9V Power Adapters LabSmith510-DL CON-1 Conductivity Electrode CON-0.1 Conductivity Electrode Conductivity Standard Solutions (84µS, 1413µS, 12.88mS) DC9V Power Adapters LabSmith510-DH CON-1 Conductivity Electrode CON-10 Conductivity Electrode Conductivity Standard Solutions (84µS, 1413µS, 12.88mS) DC9V Power Adapters - Additional Information
-
Additional Information