jainsonsindia partners
 Enquiry Cart

Vertical Laminar Air Flow Cabinet -162

More Views

Vertical Laminar Air Flow Cabinet -162

Code:

Vertical Laminar Air Flow Cabinet -162

Application & Key Feature

  • It is used for various works that require maintenance of the cleanliness and purity like plant tissue culture, examination and experimentation of precision electronics parts, medical sciences, pharmacy, agriculture sector and the like.
  • Designed so as to meet the requirements of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100 (Class conditions).
  • Cabinets is fabricated of Wooden board laminated with sunmica or cold rolled steel duly powder coated / PCGI OR stainless steel (SS-304grade)(as ordered).
  • Working table is made of Stainless Steel Sheet (SS-304 grade).
  • Front door is made out of thick transparent plexi glass.
  • Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger.
  • Heavy Duty Motor operates with minimum noise level.
  • Using a dynamic machine, the blower and motor assembly is statically & dynamically balanced.
  • Working area is illuminated by fluorescent lighting fitted to the unit.
  • Supplied complete with S.S. Table Top, Transparent front door, Static Pressure Manometer, Built in U.V. Germicidal light and Cock for gas, air or vacuum line, HEPA filters and pre-filter.
  • The highly efficient HEPA filter maintains the optimum cleanliness and purity.
  • The prefilter fitted extends the life of HEPA filter drastically.
  • Silent Vibration-Free Blower ensure noiseless operation and anti-vibration construction provides efficient working environment.
  • Interlocking of U.V. Germicidal Tube & Fluorescent Light with auto switch off/on Mode for blower when the door is closed/open.
  • All units with MOC : Wooden/CRC or PCGI/Stainless Steel are mounted on a heavy duty mild steel stand duly powder coated.
  • With Solid Side Walls and transparent front door.
  • To work on 220/230 volts A.C. supply.

Technical Specifications

 

  • MOC (CABINET): Wooden/CRC or PCGI/Stainless Steel
  • Purity: Confirming to class 100 conditions
  • Main filter: HEPA Filter (99.97% efficient at 0.3 micron parties)
  • Prefilter: High efficiency prefilter.
  • Illumination: Fluorescent Lamp 40W
  • Sterilizing: UV Germicidal Tube.
  • Utility: Gas/Air cock and multipoint 15/5 Amp. Electric socket.
  • Supply Voltage & Frequency: AC 230V, 50/60 Hz

 

 Ordering Informations

Cat. No.

Internal Workzone Dimension (LxDxH) mm.

Body Material

No. of HEPA Filter

LI-13300/1

Vertical Laminar Flow Cabinet600x600x600 mm

MOC Wooden

1

LI-13300/2

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC Wooden

1

LI-13300/3

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC Wooden

1

LI-13300/4

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC Wooden

2

LI-13300/5

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC Wooden

2

LI-13300/6

Vertical Laminar Flow Cabinet600x600x600 mm

MOC PCGI

1

LI-13300/7

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC PCGI

1

LI-13300/8

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC PCGI

1

LI-13300/9

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC PCGI

2

LI-13300/10

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC PCGI

2

LI-13300/11

Vertical Laminar Flow Cabinet600x600x600 mm

MOC Stainless Steel 304

1

LI-13300/12

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC Stainless Steel 304

1

LI-13300/13

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC Stainless Steel 304

1

LI-13300/14

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC Stainless Steel 304

2

LI-13300/15

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC Stainless Steel 304

2

 

Options

Cat. No.

Options

LI-13301/1

 Magnehelic Gauge (To track filter pressure) in lieu of static pressure manometer

LI-13301/2

 Electronic Filter choke alarm. (Differential pressure monitor)

LI-13301/3

Interlocking of U.V. Germicidal Tube & Fluorescent Light with auto switch off/on

mode for blower when the door is closed/open.

LI-13301/4

Microprocessor LCD Controller with Auto Switch off mode for motor blower when

door is closed. Digital buzzer timer sounds an audio alarm in completion of sterilizing

time of the chamber and the switches off U.V. germicidal tune and automatically switches

ON the fluorescent light, alerting the user that the bench is ready for use.

LI-13301/5

 -do- same as above but with airflow velocity sensor

LI-13301/6

 Stainless Steel SS-304, square pipe stand in lieu of MS stand to cost extra  for different model

LI-13301/7

 ULPA Filter in lieu of HEPA Filter to cost extra for different model

 

Description

Details

Vertical Laminar Air Flow Cabinet -162

Application & Key Feature

  • It is used for various works that require maintenance of the cleanliness and purity like plant tissue culture, examination and experimentation of precision electronics parts, medical sciences, pharmacy, agriculture sector and the like.
  • Designed so as to meet the requirements of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100 (Class conditions).
  • Cabinets is fabricated of Wooden board laminated with sunmica or cold rolled steel duly powder coated / PCGI OR stainless steel (SS-304grade)(as ordered).
  • Working table is made of Stainless Steel Sheet (SS-304 grade).
  • Front door is made out of thick transparent plexi glass.
  • Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger.
  • Heavy Duty Motor operates with minimum noise level.
  • Using a dynamic machine, the blower and motor assembly is statically & dynamically balanced.
  • Working area is illuminated by fluorescent lighting fitted to the unit.
  • Supplied complete with S.S. Table Top, Transparent front door, Static Pressure Manometer, Built in U.V. Germicidal light and Cock for gas, air or vacuum line, HEPA filters and pre-filter.
  • The highly efficient HEPA filter maintains the optimum cleanliness and purity.
  • The prefilter fitted extends the life of HEPA filter drastically.
  • Silent Vibration-Free Blower ensure noiseless operation and anti-vibration construction provides efficient working environment.
  • Interlocking of U.V. Germicidal Tube & Fluorescent Light with auto switch off/on Mode for blower when the door is closed/open.
  • All units with MOC : Wooden/CRC or PCGI/Stainless Steel are mounted on a heavy duty mild steel stand duly powder coated.
  • With Solid Side Walls and transparent front door.
  • To work on 220/230 volts A.C. supply.

Technical Specifications

 

  • MOC (CABINET): Wooden/CRC or PCGI/Stainless Steel
  • Purity: Confirming to class 100 conditions
  • Main filter: HEPA Filter (99.97% efficient at 0.3 micron parties)
  • Prefilter: High efficiency prefilter.
  • Illumination: Fluorescent Lamp 40W
  • Sterilizing: UV Germicidal Tube.
  • Utility: Gas/Air cock and multipoint 15/5 Amp. Electric socket.
  • Supply Voltage & Frequency: AC 230V, 50/60 Hz

 

 Ordering Informations

Cat. No.

Internal Workzone Dimension (LxDxH) mm.

Body Material

No. of HEPA Filter

LI-13300/1

Vertical Laminar Flow Cabinet600x600x600 mm

MOC Wooden

1

LI-13300/2

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC Wooden

1

LI-13300/3

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC Wooden

1

LI-13300/4

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC Wooden

2

LI-13300/5

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC Wooden

2

LI-13300/6

Vertical Laminar Flow Cabinet600x600x600 mm

MOC PCGI

1

LI-13300/7

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC PCGI

1

LI-13300/8

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC PCGI

1

LI-13300/9

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC PCGI

2

LI-13300/10

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC PCGI

2

LI-13300/11

Vertical Laminar Flow Cabinet600x600x600 mm

MOC Stainless Steel 304

1

LI-13300/12

Vertical Laminar Flow Cabinet 900x600x600 mm

MOC Stainless Steel 304

1

LI-13300/13

Vertical Laminar Flow Cabinet 1200x600x600 mm

MOC Stainless Steel 304

1

LI-13300/14

Vertical Laminar Flow Cabinet 1800x600x600 mm

MOC Stainless Steel 304

2

LI-13300/15

Vertical Laminar Flow Cabinet 2400x600x600 mm

MOC Stainless Steel 304

2

 

Options

Cat. No.

Options

LI-13301/1

 Magnehelic Gauge (To track filter pressure) in lieu of static pressure manometer

LI-13301/2

 Electronic Filter choke alarm. (Differential pressure monitor)

LI-13301/3

Interlocking of U.V. Germicidal Tube & Fluorescent Light with auto switch off/on

mode for blower when the door is closed/open.

LI-13301/4

Microprocessor LCD Controller with Auto Switch off mode for motor blower when

door is closed. Digital buzzer timer sounds an audio alarm in completion of sterilizing

time of the chamber and the switches off U.V. germicidal tune and automatically switches

ON the fluorescent light, alerting the user that the bench is ready for use.

LI-13301/5

 -do- same as above but with airflow velocity sensor

LI-13301/6

 Stainless Steel SS-304, square pipe stand in lieu of MS stand to cost extra  for different model

LI-13301/7

 ULPA Filter in lieu of HEPA Filter to cost extra for different model

 

Additional Information

Additional Information

Code No
Reviews