jainsonsindia partners
 Enquiry Cart

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD

MEASUREMENT OF LEVEL BY CAPACITANCE METHOD

Code:
DESCRIPTION :
The present set-up is designed to study the working principle and calibration procedure of capacitance type level transmitter. The set-up consists of a probe which is mounted in a level tank with graduated scale. Water is poured in the level tank manually and response of the level transmitter is indicated on the Level Indicator. Output of the transmitter can be measured using Digital Current meter. A drain valve is provided at the bottom of the level tank which enables the student to observe and measure the response of capacitance type level transmitter at different liquid heights.
 
The set-up is complete with Level tank, level transmitter, current indicator and necessary piping. All component and accessories are properly mounted on the rigid MS structure and fitted on a base plate to form a table top set-up.
 
EXPERIMENTATION:
  •  To study of working principle and calibration procedure of Capacitance type level transmitter.
  •  To study of linearity, accuracy and repeatability of capacitance type level transmitter. 
UTILITIES REQUIRED :
  •  Electric supply
  •  Water supply : Initial fill
  •  Floor Drain.
  •  Bench Area : For Setup support . 
TECHNICAL DETAILS:
Capacitance type
Level Transmitter Input : 0-300 mm of water.Output : 4-20 mA DC
Digital Current Meter Digital Indication of Current output.Range 0-30 mA DC
Level Tank Acrylic/Glass, PVC
Piping Size ¼”.
An ENGLISH instruction manual will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Ordering Details:
Catalogue No Description
JIPC-014 MEASUREMENT OF LEVEL BY CAPACITANCEMETHOD
 
 
Description

Details

DESCRIPTION :
The present set-up is designed to study the working principle and calibration procedure of capacitance type level transmitter. The set-up consists of a probe which is mounted in a level tank with graduated scale. Water is poured in the level tank manually and response of the level transmitter is indicated on the Level Indicator. Output of the transmitter can be measured using Digital Current meter. A drain valve is provided at the bottom of the level tank which enables the student to observe and measure the response of capacitance type level transmitter at different liquid heights.
 
The set-up is complete with Level tank, level transmitter, current indicator and necessary piping. All component and accessories are properly mounted on the rigid MS structure and fitted on a base plate to form a table top set-up.
 
EXPERIMENTATION:
  •  To study of working principle and calibration procedure of Capacitance type level transmitter.
  •  To study of linearity, accuracy and repeatability of capacitance type level transmitter. 
UTILITIES REQUIRED :
  •  Electric supply
  •  Water supply : Initial fill
  •  Floor Drain.
  •  Bench Area : For Setup support . 
TECHNICAL DETAILS:
Capacitance type
Level Transmitter Input : 0-300 mm of water.Output : 4-20 mA DC
Digital Current Meter Digital Indication of Current output.Range 0-30 mA DC
Level Tank Acrylic/Glass, PVC
Piping Size ¼”.
An ENGLISH instruction manual will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Ordering Details:
Catalogue No Description
JIPC-014 MEASUREMENT OF LEVEL BY CAPACITANCEMETHOD
 
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:245 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 245