Universal vacuum controller for a two-point calibration of multiple vacuum sources. It comes with a chemo resistant ceramic pressure sensor. The high-resolution TFT display ensures intuitive operation and navigation. The ventilation valve works even during a power outage and aerates the vacuum chamber. In addition to the manual mode, up to 10 programs can be saved, with up to 10 pressure/time sequences, even allowing for saving the last experiment run. It is possible to manage the experiment via labworldsoft (RS 232 interface) and to connect an external PT 1000 temperature sensor to measure the temperature of all applications. The knob also emergency stops the controller and aerates the vacuum chamber. The longevity of the valves is supported by the cleaning function which can be adjusted for every application. The operation of the vacuum controller is facilitated by a choice of languages (menu). The firmware of the device can be regularly updated with the free Firmware Update Tool (via USB).
 
Techincal Data : 
Connection diameter suction side 8 mm
Connection diameter pressure side 8 mm
Connection diameter venting side 8 mm
Gas ballast valve no
Input pressure min. 1 mbar
Input pressure max. 1050 mbar
Boiling point detection yes
Solvent library yes
Two-point control yes
Analog speed vacuum control yes
Display TFT
Pressure unit / scale mbar, hPa, mmHg, Torr
Vacuum sensor yes
Vacuum sensor type ceramic Al2O3
Pressure max. for pressure sensor 1.6 bar
Measurement range (absolute) min. 1 mbar
Measurement range (absolute) max. 1100 mbar
Control range min. 1 mbar
Control range max. 1100 mbar
Resolution pressure 1 mbar
Measurement uncertainty 1 mbar
Medium temperature (gas) min. 5 °C
Medium temperature (gas) max. 40 °C
Vacuum valve yes
Venting valve yes
Condensate trap no
Emission condenser no
Connection for ext. temperature sensor PT1000
Temperature unit °C / °F
Temperature measuring range min. -10 °C
Temperature measuring range max. 200 °C
Temperature measurement resolution 1 K
Accuracy of temperature measurement ±1 K
Timer yes
Time setting min. 1 s
Time setting max. 6000 min
Two dot vacuum control interface VC2.4
Vacuum speed control interface MVP 10 digital
Material in contact with medium Al2O3, PTFE, FPM, PPS
housing material PBT
clean room qualified no
explosion proofed no
Fastening stand / clamp
Fastening diameter 16 mm
Dimensions (W x H x D) 95 x 150 x 110 mm
Weight 1.5 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
RS 232 interface yes
USB interface yes
Analog output no
Voltage 100 - 240 V
Frequency 50/60 Hz
Power input 24 W
Power input standby 2 W
DC Voltage 24 V=
Current consumption 1000 mA
 
Description

Details

Description :
Model No. : VC-10
Universal vacuum controller for a two-point calibration of multiple vacuum sources. It comes with a chemo resistant ceramic pressure sensor. The high-resolution TFT display ensures intuitive operation and navigation. The ventilation valve works even during a power outage and aerates the vacuum chamber. In addition to the manual mode, up to 10 programs can be saved, with up to 10 pressure/time sequences, even allowing for saving the last experiment run. It is possible to manage the experiment via labworldsoft (RS 232 interface) and to connect an external PT 1000 temperature sensor to measure the temperature of all applications. The knob also emergency stops the controller and aerates the vacuum chamber. The longevity of the valves is supported by the cleaning function which can be adjusted for every application. The operation of the vacuum controller is facilitated by a choice of languages (menu). The firmware of the device can be regularly updated with the free Firmware Update Tool (via USB).
 
Techincal Data : 
Connection diameter suction side 8 mm
Connection diameter pressure side 8 mm
Connection diameter venting side 8 mm
Gas ballast valve no
Input pressure min. 1 mbar
Input pressure max. 1050 mbar
Boiling point detection yes
Solvent library yes
Two-point control yes
Analog speed vacuum control yes
Display TFT
Pressure unit / scale mbar, hPa, mmHg, Torr
Vacuum sensor yes
Vacuum sensor type ceramic Al2O3
Pressure max. for pressure sensor 1.6 bar
Measurement range (absolute) min. 1 mbar
Measurement range (absolute) max. 1100 mbar
Control range min. 1 mbar
Control range max. 1100 mbar
Resolution pressure 1 mbar
Measurement uncertainty 1 mbar
Medium temperature (gas) min. 5 °C
Medium temperature (gas) max. 40 °C
Vacuum valve yes
Venting valve yes
Condensate trap no
Emission condenser no
Connection for ext. temperature sensor PT1000
Temperature unit °C / °F
Temperature measuring range min. -10 °C
Temperature measuring range max. 200 °C
Temperature measurement resolution 1 K
Accuracy of temperature measurement ±1 K
Timer yes
Time setting min. 1 s
Time setting max. 6000 min
Two dot vacuum control interface VC2.4
Vacuum speed control interface MVP 10 digital
Material in contact with medium Al2O3, PTFE, FPM, PPS
housing material PBT
clean room qualified no
explosion proofed no
Fastening stand / clamp
Fastening diameter 16 mm
Dimensions (W x H x D) 95 x 150 x 110 mm
Weight 1.5 kg
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 20
RS 232 interface yes
USB interface yes
Analog output no
Voltage 100 - 240 V
Frequency 50/60 Hz
Power input 24 W
Power input standby 2 W
DC Voltage 24 V=
Current consumption 1000 mA
 
Additional Information