jainsonsindia partners
 Enquiry Cart

Recirculating Coolers

Code:
Recirculating Coolers (High Temp.)
Broad temperature ranging up to 80°C for various applications.
Also integrated heaters greatly provides high temperature stability.
Performance
  • Wide temperature range from -20°Cto 80°C.
  • High cooling capacity up to 7.1kW at 20°C.
  • Powerful circulating pumps up to to70L/min., 6 bar.
  • Precise temperature stability ± 0.1°C(at 15°C) with integrated heaters.
  • Refrigerating system is designed to reduce energy consumption and maximize refrigerating efficiency.
Convenience
  • Designed to simplify operation with a touch screen type display.
     - Setting and resolution indication 0.1°C/°F.
     - Quick keypad lock prevents accidental parameter changes.
  • Bright LED water level indicator can be seen from a distance.
  • Optional external sensor can be connected for more actual temperature control.
  • Built in pressure gauge for checking pump pressure at a glance.
  • High/low pressure gauges for condition diagnosis of refrigerating system at a glance
  • Wide filling inlet for easy and safe pouring of solution into the unit.
  • Double service valve prevents refrigerant leakage for easy maintenance.
  • Removable gridded vent for easy maintenance of condenser.
  • Built-in casters for easy transport and installation.
  • RS-232 interface for external control and data collection.
Safety
  • Self-diagnostic function identifying errors.
  • Complete safety protection system with warning alarms.
     - Low fluid level and dry-running protection; when triggered shows an error symbol on the display and an audible buzzer sound.
     - Over-temperature protection; If the equipment operates at over maximum temperature due to external environment, user can simply identify the error with a visual signal or an audible buzzer sound.
     - Over-current circuit breaker.
  • Eco-friendly R-404A / R-507 refrigerant use for environmental protection.
  • Splash-proof keypad.
Model LSHH-15 LSHH-20 LSHH-25 LSHH-35 LSHH-45H  LSHH-55H 
Temperature 1) (bath fluid : ethylene glycol mix 1:1 water) Working temperature range (℃ / ℉) -20 to 80 / - 4 to 176
Temperature stabilityat 15℃ (±℃ / ℉) 0.1 / 0.2
Cooling capacity(bath Fluid : ethylene glycol mix 1:1 water) at 80℃ (kw) 2 2.5 3.5 4 6 7.5
at 40℃ (kw) 0.9 1 2.4 2.5 4.5 5
at 20℃ (kw) 1.45 1.8 2.5 3.3 6.5 7.1
at 0℃ (kw) 0.86 1.15 1.1 1.7 3 4.1
at -20℃ (kw) 0.3 0.4 0.4 0.55 1.2 1.5
Heating capacity(kw) 2 4 8.4
Pump Max. flow rate(L / min, gal / min) 40 / 10.6 70 / 18.5
Max. pressure (bar / psi) 3.3 / 47.9 6 / 87.02
Dimension Max. filling capacity (L, cu ft) 13.5 / 0.47 25 / 0.88 39 / 1.37
For tubing dia. (mm / inch) 20 / 3/4
Filling inlet (Ø, mm / inch) 120 / 4.7
Overall (WxDxH, mm / inch) 515×715× 835/ 20.3×28.1×32.9 550×900×1140/ 21.7×35.4×44.9 605×1045×1300/ 23.8×41.4×51.2
Net weight (kg / Ibs) 92 / 202.8 93 / 205 142 / 313 147 / 324 171±10/ 377±22 176±10/ 388±22
Electric requirement (230V, 60Hz) 15A 16A 27A 31A    
Electric requirement (230V, 50Hz) 14.5A 15.5A 25A 30A    
 
1) Technical data according to DIN 12876.
Description

Details

Recirculating Coolers (High Temp.)
Broad temperature ranging up to 80°C for various applications.
Also integrated heaters greatly provides high temperature stability.
Performance
  • Wide temperature range from -20°Cto 80°C.
  • High cooling capacity up to 7.1kW at 20°C.
  • Powerful circulating pumps up to to70L/min., 6 bar.
  • Precise temperature stability ± 0.1°C(at 15°C) with integrated heaters.
  • Refrigerating system is designed to reduce energy consumption and maximize refrigerating efficiency.
Convenience
  • Designed to simplify operation with a touch screen type display.
     - Setting and resolution indication 0.1°C/°F.
     - Quick keypad lock prevents accidental parameter changes.
  • Bright LED water level indicator can be seen from a distance.
  • Optional external sensor can be connected for more actual temperature control.
  • Built in pressure gauge for checking pump pressure at a glance.
  • High/low pressure gauges for condition diagnosis of refrigerating system at a glance
  • Wide filling inlet for easy and safe pouring of solution into the unit.
  • Double service valve prevents refrigerant leakage for easy maintenance.
  • Removable gridded vent for easy maintenance of condenser.
  • Built-in casters for easy transport and installation.
  • RS-232 interface for external control and data collection.
Safety
  • Self-diagnostic function identifying errors.
  • Complete safety protection system with warning alarms.
     - Low fluid level and dry-running protection; when triggered shows an error symbol on the display and an audible buzzer sound.
     - Over-temperature protection; If the equipment operates at over maximum temperature due to external environment, user can simply identify the error with a visual signal or an audible buzzer sound.
     - Over-current circuit breaker.
  • Eco-friendly R-404A / R-507 refrigerant use for environmental protection.
  • Splash-proof keypad.
Model LSHH-15 LSHH-20 LSHH-25 LSHH-35 LSHH-45H  LSHH-55H 
Temperature 1) (bath fluid : ethylene glycol mix 1:1 water) Working temperature range (℃ / ℉) -20 to 80 / - 4 to 176
Temperature stabilityat 15℃ (±℃ / ℉) 0.1 / 0.2
Cooling capacity(bath Fluid : ethylene glycol mix 1:1 water) at 80℃ (kw) 2 2.5 3.5 4 6 7.5
at 40℃ (kw) 0.9 1 2.4 2.5 4.5 5
at 20℃ (kw) 1.45 1.8 2.5 3.3 6.5 7.1
at 0℃ (kw) 0.86 1.15 1.1 1.7 3 4.1
at -20℃ (kw) 0.3 0.4 0.4 0.55 1.2 1.5
Heating capacity(kw) 2 4 8.4
Pump Max. flow rate(L / min, gal / min) 40 / 10.6 70 / 18.5
Max. pressure (bar / psi) 3.3 / 47.9 6 / 87.02
Dimension Max. filling capacity (L, cu ft) 13.5 / 0.47 25 / 0.88 39 / 1.37
For tubing dia. (mm / inch) 20 / 3/4
Filling inlet (Ø, mm / inch) 120 / 4.7
Overall (WxDxH, mm / inch) 515×715× 835/ 20.3×28.1×32.9 550×900×1140/ 21.7×35.4×44.9 605×1045×1300/ 23.8×41.4×51.2
Net weight (kg / Ibs) 92 / 202.8 93 / 205 142 / 313 147 / 324 171±10/ 377±22 176±10/ 388±22
Electric requirement (230V, 60Hz) 15A 16A 27A 31A    
Electric requirement (230V, 50Hz) 14.5A 15.5A 25A 30A    
 
1) Technical data according to DIN 12876.