jainsonsindia partners
 Enquiry Cart

Digital Gaussmeter

Code:
Digital Gaussmeter
 
  • Differential mode facility
  • Wide Range (1G to 40KG)
  • Excellent Linearity
  • Excellent Stability
  • Easy replacement of Hall Probe
 
Introduction 
LSDGM-103 operates on the principle of Hall Effect in Semiconductors. A semiconductor carrying current develops an electromotive force, when placed in a magnetic field, in a direction perpendicular to the direction of both electric current and magnetic field. The magnitude of this e.m.f. is proportional to the field intensity if the current is kept constant. This e.m.f. is called the Hall Voltage. The small Hall Voltage is amplified through a high stability amplifier so that a millivoltmeter connected at the output of the amplifier can be calibrated directly in magnetic field unit (gauss).
 
Applications
  • Wide application in industry where accurate measurements of magnetic field is required.
  • Measurement of steady magnetic field e.g. in loud speakers, dynamo, moving coil instruments etc.
  • Useful in laboratory experiment involving measurement of magnetic field.
  • With the differential mode facility, the instrument is especially useful for testing the homogeneity/variation of magnetic field in a particular region .
 
Specifications
Model LSDGM-103
Range 0-2KG, 0-20KG & 0-40KG
Resolution 1G at 0-2KG range in normal mode 
1G at 20KG & 40KG range in differential mode
Accuracy ±0.5%
Temperature Upto 50°C
Display 3½ digit, 7 segment LED DPM with auto polarity and overflow indication
Power 220V ±10%, 50Hz
Transducer Hall Probe – InAs
Special Feature Indicate the direction of the magnetic field
Weight 3Kg
Dimensions 280mm X 255mm X 120mm
 
Description

Details

Digital Gaussmeter
 
  • Differential mode facility
  • Wide Range (1G to 40KG)
  • Excellent Linearity
  • Excellent Stability
  • Easy replacement of Hall Probe
 
Introduction 
LSDGM-103 operates on the principle of Hall Effect in Semiconductors. A semiconductor carrying current develops an electromotive force, when placed in a magnetic field, in a direction perpendicular to the direction of both electric current and magnetic field. The magnitude of this e.m.f. is proportional to the field intensity if the current is kept constant. This e.m.f. is called the Hall Voltage. The small Hall Voltage is amplified through a high stability amplifier so that a millivoltmeter connected at the output of the amplifier can be calibrated directly in magnetic field unit (gauss).
 
Applications
  • Wide application in industry where accurate measurements of magnetic field is required.
  • Measurement of steady magnetic field e.g. in loud speakers, dynamo, moving coil instruments etc.
  • Useful in laboratory experiment involving measurement of magnetic field.
  • With the differential mode facility, the instrument is especially useful for testing the homogeneity/variation of magnetic field in a particular region .
 
Specifications
Model LSDGM-103
Range 0-2KG, 0-20KG & 0-40KG
Resolution 1G at 0-2KG range in normal mode 
1G at 20KG & 40KG range in differential mode
Accuracy ±0.5%
Temperature Upto 50°C
Display 3½ digit, 7 segment LED DPM with auto polarity and overflow indication
Power 220V ±10%, 50Hz
Transducer Hall Probe – InAs
Special Feature Indicate the direction of the magnetic field
Weight 3Kg
Dimensions 280mm X 255mm X 120mm
 
Additional Information

Additional Information

Code No
Reviews