jainsonsindia partners
 Enquiry Cart

Magnetic Field Measurement Apparatus

More Views

Magnetic Field Measurement Apparatus

Code:

Magnetic Field Measurement Appartus

Introduction 

The experiment consists of two coils, Constant Current Power Supply and Gaussmeter. The Gaussmeter probe is mounted on a rail with a scale. It can move smoothly and precisely for measurement of magnetic field along the centre of the coils.

The following studies can be carried out with the set-up:

1. Study of magnetic field due to one coil and calculation of its diameter.

2. Study of principal of super-imposition of magnetic field due to 2 coils by keeping the distance between the coils at a, greater than a and less than a, where a is the radius of the coil.

Legend:

 Line1  Magnetic Profile when the distance between the coils is greater than a
Line 2 Magnetic Profile when the distance between coils is equal to a
Line 3 Magnetic Profile when the distance between coils is less than a – Superimposition overlaps completely

 

Apparatus consists of the following:

1. Digital Gaussmeter
Range: 0-200 

Resolution: 0.1G
Accuracy: 0.5%
Display: 3½ digit 7 segment LED with autopolarity.

2. Two Coil
Diameter: 200mm

Number of turn: 1000

3. Constant Current Power Supply
Current: 0-0.5A Smoothly adjustable

Line Regulator: 0.2%for 10% mains variation.
Load Regulator: 0.2 % for 0 to full load.
Display: 3½ digit 7 Segment LED Display.
Protection: Against overload/ short current.

The 2 coils are mounted on platform one coil is fixed and other coil move smoothly on a rail along with the axis of the coils.

Model LSMFM-01
Description

Details

Magnetic Field Measurement Appartus

Introduction 

The experiment consists of two coils, Constant Current Power Supply and Gaussmeter. The Gaussmeter probe is mounted on a rail with a scale. It can move smoothly and precisely for measurement of magnetic field along the centre of the coils.

The following studies can be carried out with the set-up:

1. Study of magnetic field due to one coil and calculation of its diameter.

2. Study of principal of super-imposition of magnetic field due to 2 coils by keeping the distance between the coils at a, greater than a and less than a, where a is the radius of the coil.

Legend:

 Line1  Magnetic Profile when the distance between the coils is greater than a
Line 2 Magnetic Profile when the distance between coils is equal to a
Line 3 Magnetic Profile when the distance between coils is less than a – Superimposition overlaps completely

 

Apparatus consists of the following:

1. Digital Gaussmeter
Range: 0-200 

Resolution: 0.1G
Accuracy: 0.5%
Display: 3½ digit 7 segment LED with autopolarity.

2. Two Coil
Diameter: 200mm

Number of turn: 1000

3. Constant Current Power Supply
Current: 0-0.5A Smoothly adjustable

Line Regulator: 0.2%for 10% mains variation.
Load Regulator: 0.2 % for 0 to full load.
Display: 3½ digit 7 Segment LED Display.
Protection: Against overload/ short current.

The 2 coils are mounted on platform one coil is fixed and other coil move smoothly on a rail along with the axis of the coils.

Model LSMFM-01
Additional Information

Additional Information

Code No
Reviews