jainsonsindia partners
 Enquiry Cart

Neptune PLUS Anesthesia Workstation

More Views

Neptune PLUS Anesthesia Workstation

Code:
Neptune PLUS Anesthesia Workstation
Features :-
  • High-luminance and wide display
  • Large screen with options of 8.1" or 10.1"
  • Ventilation modes: VCV, PCV, SIMV-V, SIMV-P, PSV, SPONT & Manual
  • Monitoring Parameters (Measured Values) V , T Frequency, FiO2 , Ppeak , MV, PEEP, Cdyn
  • Tidal volume range from 20ml to 1500ml suitable for Adult, Pediatric & Neonates
  • Volume compensation and electronic PEEP automatically compensates for fresh gas flow, system leak and the compliance change in the circuit
  • Ascending bellows provides immediate visual information on the adequacy of fresh gas flow and gives an indication of any system leak
  • Cardiac By-Pass mode Integrated pressure, volume and oxygen monitoring
  • Self test and leak test
  • Adult to pediatric mode
  • Waveforms Flow-Time waveform, Volume-Time waveform, Flow- Volume loop, Volume-Pressure loop
  • Setting Parameters V (Tidal Volume), Frequency, I:E, Tip Inspiratory pause time), Pmax, PEEP, Vsens (Triggering flow sensitivity), SIGH, Tapn, Ping (Pressure trigger), Plimit, Psupp.
  • Alarm Parameters Continuous positive airway pressure, Airway pressure (high & low), FiO2 (high & low), MV (high & low), VT (high & low), Frequency (high & low), Apnea, A/C failure, Battery low, Self-test failure
Additional Information:
Item Code Description
Neptune-PLUS Anesthesia Workstation
 
Description

Details

Neptune PLUS Anesthesia Workstation
Features :-
  • High-luminance and wide display
  • Large screen with options of 8.1" or 10.1"
  • Ventilation modes: VCV, PCV, SIMV-V, SIMV-P, PSV, SPONT & Manual
  • Monitoring Parameters (Measured Values) V , T Frequency, FiO2 , Ppeak , MV, PEEP, Cdyn
  • Tidal volume range from 20ml to 1500ml suitable for Adult, Pediatric & Neonates
  • Volume compensation and electronic PEEP automatically compensates for fresh gas flow, system leak and the compliance change in the circuit
  • Ascending bellows provides immediate visual information on the adequacy of fresh gas flow and gives an indication of any system leak
  • Cardiac By-Pass mode Integrated pressure, volume and oxygen monitoring
  • Self test and leak test
  • Adult to pediatric mode
  • Waveforms Flow-Time waveform, Volume-Time waveform, Flow- Volume loop, Volume-Pressure loop
  • Setting Parameters V (Tidal Volume), Frequency, I:E, Tip Inspiratory pause time), Pmax, PEEP, Vsens (Triggering flow sensitivity), SIGH, Tapn, Ping (Pressure trigger), Plimit, Psupp.
  • Alarm Parameters Continuous positive airway pressure, Airway pressure (high & low), FiO2 (high & low), MV (high & low), VT (high & low), Frequency (high & low), Apnea, A/C failure, Battery low, Self-test failure
Additional Information:
Item Code Description
Neptune-PLUS Anesthesia Workstation
 
Additional Information

Additional Information

Code No