Tabletop Pulse Oximeter

Code:
Tabletop Pulse Oximeter
 
Catalogue No. Description
FPO-J120a Tabletop Pulse Oximeter
 
Observer-Handheld ECG monitor ECG-100, is designed for home use with the purpose of health care. Users can choose different measurement modes as they like, 30s for easy mode or continuous mode for a long time measurement. The USB interface can fulfil the data transmission perfectly! The stored waveforms and analysis results help users do the review freely.
 
Features :
  • Compact and portable, allow uninterrupted monitoring with in-built battery
  •  High bright LED display of NIBP,SPO2 and pulse rate
  • High resolution color LCD for trend tabular and SPO2 waveforms display
  • Manual/auto/continuous measurement of NIBP
  • Adjustable audible and visual alarms
  • Up to 600 groups NIBP data & up to 10 hours
  • Suitable for adult, paediatric and neonatal patient display
  • 7 segment LED for systolic, diastolic, mean pressures,SPO2 and pulse rate
  • 2.4``color LCD for waveforms, bar graph, trend and system menu
 
Nibp
 
Method Oscillometry
Operation Modes Manual/Automatic/STAT
Auto Measure Time 5-250 Minutes Adjustable,Interval 5 Minutes
Measurement Range 10-270mmHg
Over Pressue Protection Yes
Resolution 1mmHg
Alarm Systolic,Dia
 
SPO2
 
Measurement 0-100%
Resolution 1%
Accuracy 70-100% ± Or ± 2%,0-69% Unspecified
Alarm Range 0-100%
 
Description

Details

Tabletop Pulse Oximeter
 
Catalogue No. Description
FPO-J120a Tabletop Pulse Oximeter
 
Observer-Handheld ECG monitor ECG-100, is designed for home use with the purpose of health care. Users can choose different measurement modes as they like, 30s for easy mode or continuous mode for a long time measurement. The USB interface can fulfil the data transmission perfectly! The stored waveforms and analysis results help users do the review freely.
 
Features :
  • Compact and portable, allow uninterrupted monitoring with in-built battery
  •  High bright LED display of NIBP,SPO2 and pulse rate
  • High resolution color LCD for trend tabular and SPO2 waveforms display
  • Manual/auto/continuous measurement of NIBP
  • Adjustable audible and visual alarms
  • Up to 600 groups NIBP data & up to 10 hours
  • Suitable for adult, paediatric and neonatal patient display
  • 7 segment LED for systolic, diastolic, mean pressures,SPO2 and pulse rate
  • 2.4``color LCD for waveforms, bar graph, trend and system menu
 
Nibp
 
Method Oscillometry
Operation Modes Manual/Automatic/STAT
Auto Measure Time 5-250 Minutes Adjustable,Interval 5 Minutes
Measurement Range 10-270mmHg
Over Pressue Protection Yes
Resolution 1mmHg
Alarm Systolic,Dia
 
SPO2
 
Measurement 0-100%
Resolution 1%
Accuracy 70-100% ± Or ± 2%,0-69% Unspecified
Alarm Range 0-100%
 