jainsonsindia partners
 Enquiry Cart

Horizontal cylindrical pressure steam sterilizer

More Views

Horizontal cylindrical pressure steam sterilizer

Code:
Horizontal cylindrical pressure steam sterilizer
Characteristics:
1. Sterilizing course automatic sterilization controlled, easy to operate.
2. With drying function, suitable dressing drying.
3. With over-temperature, over-pressure auto-protect device.
4. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
6. The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
7. The chamber of the sterilizer is made of stainless steel.
Technical data:
MODEL JWS-90YDA JWS-150YDA JWS-200YDA JWS-280YDA JWS-400YDA JWS-500YDA
Sterilizing chambervolume 90Lφ440 × 700mm 150Lφ440 × 1000mm 200Lφ515 × 1000mm 280Lφ600 × 1000mm 400LΦ700 × 1100mm 500LΦ700 × 1300mm
working pressure 0.22MPa
working  temperature 134℃
Adjustment of temperature 105℃ - 134℃
Time of sterilization 0-60 min
Time of drying 0-60 min
Heat average ≤±1℃
Power 9KW/380V 50Hz 9KW/380V 50Hz 9KW/380V 50Hz 12KW/380V 50Hz 18KW/380V 50Hz 18KW/380V 50Hz
Dimension 1100×600×1300 1400×600×1300 1400×670×1650 1400×770×1780 1430×880×1830 1800×900×1820
Transport dimension 1250×750×1850 1550×750×1850 1560×820×1850 1680×920×2100 1800×1050×2100 1850×1050×2100
G.W/N.W 270/200 KG 320/240 KG 350/260 KG 465/365 KG 530/520 KG 580/470 KG
 
Description

Details

Horizontal cylindrical pressure steam sterilizer
Characteristics:
1. Sterilizing course automatic sterilization controlled, easy to operate.
2. With drying function, suitable dressing drying.
3. With over-temperature, over-pressure auto-protect device.
4. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
6. The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
7. The chamber of the sterilizer is made of stainless steel.
Technical data:
MODEL JWS-90YDA JWS-150YDA JWS-200YDA JWS-280YDA JWS-400YDA JWS-500YDA
Sterilizing chambervolume 90Lφ440 × 700mm 150Lφ440 × 1000mm 200Lφ515 × 1000mm 280Lφ600 × 1000mm 400LΦ700 × 1100mm 500LΦ700 × 1300mm
working pressure 0.22MPa
working  temperature 134℃
Adjustment of temperature 105℃ - 134℃
Time of sterilization 0-60 min
Time of drying 0-60 min
Heat average ≤±1℃
Power 9KW/380V 50Hz 9KW/380V 50Hz 9KW/380V 50Hz 12KW/380V 50Hz 18KW/380V 50Hz 18KW/380V 50Hz
Dimension 1100×600×1300 1400×600×1300 1400×670×1650 1400×770×1780 1430×880×1830 1800×900×1820
Transport dimension 1250×750×1850 1550×750×1850 1560×820×1850 1680×920×2100 1800×1050×2100 1850×1050×2100
G.W/N.W 270/200 KG 320/240 KG 350/260 KG 465/365 KG 530/520 KG 580/470 KG
 
Additional Information

Additional Information

Code No