jainsonsindia partners
 Enquiry Cart

MNRU1101B Fixed Cradle + 3 Drawers

More Views

MNRU1101B Fixed Cradle + 3 Drawers

Code:

MNRU1101B Fixed Cradle + 3 Drawers

General Description

  • Mobile Radiant Heat Warmer - Fixed Height
  • Mounted on 4 swivel castors (100mm) - 2 castors with brake
  • Baby tray with mattress along with head up/down facility and X-ray cassette holder
  • Mattress density approx. 21-25 kg/m3 and removable, washable, water proof cover
  • 6mm thick - Transparent acrylic drop down and lockable side panel
  • Side tray for monitor and infusion rod for syringe pump/SS IV rod
  • 2 shelves below baby bed for under surface Phototherapy and storage
  • Under table plastic moulded 3 storage drawers
  • FR grade moulded swivelling hood suspended above the table integrates heating element and overhead light
  • Heating element – Ceramic heater (650 W) with parabolic reflector, protected by metallic grid

Oxygenation:

  • Integrated support for 10L oxygen Cylinder
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient

Suction:

  • Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable
  • Fluid Jar 500ml (2 nos.) and Silicone tubing

Resuscitation:

  • Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks.
  • Laryngoscope - Penlight handle with size 0 and 1 straight blade
  • Silicone Airways size 000, 00 and 0

Temperature Controller B

  • Big red LED display for skin temperature, set temperature & timer
  • LED indicator for selected mode & alarm
  • Bar-graph for heater power
  • Integrated timer – 1 to 09 min with count-up feature
  • Temperature range – skin: 34 to 38°C (user pre-settable)
  • Monitoring of skin temperature by means of sensor, range: 30 to 42°C
  • Control unit – auto over-temperature cut-off with audio-visual alarms according to pre-set temperature to avoiding overheating
  • Display indicates system errors, sensor failure, alarm for high/low, over/under temperature for skin, heater failure, power control device failure.
  • Audio-Visual alarm for power failure
Description

Details

MNRU1101B Fixed Cradle + 3 Drawers

General Description

  • Mobile Radiant Heat Warmer - Fixed Height
  • Mounted on 4 swivel castors (100mm) - 2 castors with brake
  • Baby tray with mattress along with head up/down facility and X-ray cassette holder
  • Mattress density approx. 21-25 kg/m3 and removable, washable, water proof cover
  • 6mm thick - Transparent acrylic drop down and lockable side panel
  • Side tray for monitor and infusion rod for syringe pump/SS IV rod
  • 2 shelves below baby bed for under surface Phototherapy and storage
  • Under table plastic moulded 3 storage drawers
  • FR grade moulded swivelling hood suspended above the table integrates heating element and overhead light
  • Heating element – Ceramic heater (650 W) with parabolic reflector, protected by metallic grid

Oxygenation:

  • Integrated support for 10L oxygen Cylinder
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient

Suction:

  • Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable
  • Fluid Jar 500ml (2 nos.) and Silicone tubing

Resuscitation:

  • Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks.
  • Laryngoscope - Penlight handle with size 0 and 1 straight blade
  • Silicone Airways size 000, 00 and 0

Temperature Controller B

  • Big red LED display for skin temperature, set temperature & timer
  • LED indicator for selected mode & alarm
  • Bar-graph for heater power
  • Integrated timer – 1 to 09 min with count-up feature
  • Temperature range – skin: 34 to 38°C (user pre-settable)
  • Monitoring of skin temperature by means of sensor, range: 30 to 42°C
  • Control unit – auto over-temperature cut-off with audio-visual alarms according to pre-set temperature to avoiding overheating
  • Display indicates system errors, sensor failure, alarm for high/low, over/under temperature for skin, heater failure, power control device failure.
  • Audio-Visual alarm for power failure
Additional Information

Additional Information

Code No