jainsonsindia partners
 Enquiry Cart

MNRU1102A Fixed Cradle

Code:

MNRU1102A Fixed Cradle

General Description

  • Mobile radiant heat warmer-fixed height
  • Mounted on 4 swivel castors (100mm) - 2 castors with brake
  • Baby tray with mattress along with head up/down facility and X-ray cassette holder
  • Mattress density approx. 21-25 kg/m3 and removable washable water proof cover
  • 6mm thick - Transparent acrylic drop down and lockable side panel
  • Side tray for monitor and infusion rod for syringe pump/SS IV rod
  • 2 shelves below baby bed for under surface Phototherapy and storage
  • FR grade moulded swivelling hood suspended above the table integrates heating element and overhead light
  • Heating element – Ceramic heater (650 W) with parabolic reflector, protected by metallic grid

Oxygenation:

  • Integrated support for 10L oxygen Cylinder
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient

Suction:

  • Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable
  • Fluid Jar 500ml (2 nos.) and Silicone tubing

Resuscitation:

  • Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks.
  • Laryngoscope - Penlight handle with size 0 and 1 straight blade
  • Silicone Airways size 000, 00 and 0

Temperature Controller A

  • Big red LED display for skin and air temperature
  • LED indicator for selected mode
  • LCD for alarm messages, selected mode, timer display, heater power (%), etc.
  • Integrated timer – 1 to 59 min with count-up and count-down feature
  • Temperature range – skin: 34 to 38°C (user pre-settable) air: room temperature to 39°C
  • Monitoring of skin temperature by means of sensor, range: 30 to 42°C
  • Heater output – 0 to 100% in increments of 5%
  • Control unit – Auto over-temperature cut-off with audio-visual alarms according to pre-set temperature to avoiding overheating
  • Display indicates system errors, sensor failure, alarm and visual message on LCD for high/low, over/under temperature for skin and air, heater failure, power control device failure.
  • Audio-Visual alarm for power failure
Description

Details

MNRU1102A Fixed Cradle

General Description

  • Mobile radiant heat warmer-fixed height
  • Mounted on 4 swivel castors (100mm) - 2 castors with brake
  • Baby tray with mattress along with head up/down facility and X-ray cassette holder
  • Mattress density approx. 21-25 kg/m3 and removable washable water proof cover
  • 6mm thick - Transparent acrylic drop down and lockable side panel
  • Side tray for monitor and infusion rod for syringe pump/SS IV rod
  • 2 shelves below baby bed for under surface Phototherapy and storage
  • FR grade moulded swivelling hood suspended above the table integrates heating element and overhead light
  • Heating element – Ceramic heater (650 W) with parabolic reflector, protected by metallic grid

Oxygenation:

  • Integrated support for 10L oxygen Cylinder
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient

Suction:

  • Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable
  • Fluid Jar 500ml (2 nos.) and Silicone tubing

Resuscitation:

  • Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks.
  • Laryngoscope - Penlight handle with size 0 and 1 straight blade
  • Silicone Airways size 000, 00 and 0

Temperature Controller A

  • Big red LED display for skin and air temperature
  • LED indicator for selected mode
  • LCD for alarm messages, selected mode, timer display, heater power (%), etc.
  • Integrated timer – 1 to 59 min with count-up and count-down feature
  • Temperature range – skin: 34 to 38°C (user pre-settable) air: room temperature to 39°C
  • Monitoring of skin temperature by means of sensor, range: 30 to 42°C
  • Heater output – 0 to 100% in increments of 5%
  • Control unit – Auto over-temperature cut-off with audio-visual alarms according to pre-set temperature to avoiding overheating
  • Display indicates system errors, sensor failure, alarm and visual message on LCD for high/low, over/under temperature for skin and air, heater failure, power control device failure.
  • Audio-Visual alarm for power failure
Additional Information