jainsonsindia partners
 Enquiry Cart

Portable ETCO2 Monitor

Code:
Portable ETCO2 Monitor
Portable  ETCO2  Monitor works on Principle of operation Solid state side stream module. Single beam, non-dispersive infrared (NDIR) absorption, ratio metric measurement.
Product Details:
Catalogue No JTM-109
Usage Hospitals, Clinical Use
Handling Options Portable
Features Networkable

Specification :-
  • Initialization time Capnogram within 10 sec., full specifications within 60 sec.
  • Calibration Routine calibration is not required. 8sec zero performed when power on or ambient temperature changing too faster.
  • Sampling flow rate 100 ml/min (can be set from 50 to 200ml/min).
  • CO2 (Carbon dioxide) Compensations: N2O & O2 (selectable), BP (automatic) Capnogram: Selectable sweep speed (4.41, 8.82, or 17.64mm/sec) Range: 0 - 150 mmHg Accuracy: ±2 mmHg (for 0 - 40 mmHg) ±5% of reading (for 41 - 70 mmHg) ±8% of reading (for 71 - 150 mmHg) Resolution: 1 mmHg Response Time: 28 ms
  • Respiratory rate Accuracy: ±1 br/min Range: 0-150 br/min Resolution: 1 br/min
  • Pulse Oximeter Model TM 109 ETCO2/SPO2 monitor
  • Principle of operation Red/Infrared absorption.
  • SpO2 (Oxygen saturation) Range: 0-100% Accuracy: ±2% SpO2 (for 80-100% SpO2) ±3% SpO2 (for 50-79% SpO2) (1 SD, or 68% of readings within claim) Unspecified for 0-49% SpO2 Resolution: 1% Averaging: 8 sec.
  • Pulse rate Range: 20-254 bpm Accuracy: ±1% of full scale Resolution: 1 bpm Averaging: 8 sec.
  • SENSORS Reusable Y-Sensor (can be sterilized and used with all patient populations); reusable adult finger sensor.
  • Plethysmogram Pulsatile waveform with autogain.
  • General Alerts Limits: Adjustable limits for ETCO2, SpO2, Respiratory and Pulse Rates Audio: 3 model adjustable volume, silence or OFF Visual: On-screen & red or yellow background with black text
  • Display Type: LCD with backlinghting Size: 5.6"( 144.8mmW*110.2mmH, 640*480) Physical Size: 175mm H * 240mm W * 140mm D Weight: 1.8 kg
  • Electrical Power requirements: 100-120/200-240 VAC, 50-60 Hz, 24VA Battery: Li, 5hr. life, 5 hr. recharge
  • Environmental Operating temperature: 10-50° C Operating humidity: 0-90% relative (non-condensing) 
Features: 
  • Supports adult, pediatric and neonatal patient
  • Alarms for high and low ETCO2, respiratory rate, SPO2 value, pulse rate.
  • Color-coded graphic
  • Standard with sidestream ETCO2, easily change to mainstream by advanced order.
  • Power on and go
  • Silence or temporarily pause alarms
  • Quick to learn, easy to use
  • Push function keys according prompt
  • Universal icons with single-level menus
  • Flexible, portable and lightweight
  • Minimum 5 hours operating time
  • Supports battery exchange without loss of power
  • Weighs 1.8 kg. with four battery waveforms and up to eight parameters using a 14.2 cm (5.6 in) LCD.
 

Be the first to review this product

Write Your Own Review

You're reviewing: Portable ETCO2 Monitor

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value