The New Lab All Quartz Double Distiller has been redesigned for better performance keeping in view customer requirements. These improved models have larger boiler vessels, more condensing space to eliminate certain disadvantages of the earlier versions. It is now more compact with a more balanced boiling. The new models render better performance and improved quality of distillate.
TECHNICAL SPECIFICATIONS
Models |
LAQD-01-DB
|
LAQD-1.5-DB
|
LAQD-02-DB
|
LAQD-2.5-DB
|
LAQD-03-DB
|
LAQD-04-DB
|
LAQD-05-DB
|
Output capacity(Approx.)
|
1.0 ltr/hr
|
1.5 ltrs/hr
|
2.0 ltrs/hr
|
2.5 ltrs/hr
|
3.0 ltrs/hr
|
4.0 ltrs/hr
|
5.0 ltrs/hr
|
Power Rating (total)
|
2 KW
|
2.75 KW
|
3.5 KW
|
4.5 KW
|
5.0 KW
|
6.0 KW**
|
7.0 KW**
|
Cooling Water Consumption approx.
|
2 ltrs/min
|
2.5 ltrs/min
|
3 ltrs/min
|
3.5 ltrs/min
|
3.8 ltrs/min
|
4.5 ltrs/min
|
6 ltrs/min
|
Double Distillate Quality
Parameters
|
Values
|
Specific Conductivity
|
0.1 - 0.5 µS/cm
|
Total Solids
|
0.1 mg /ltr
|
Silica
|
<0.01 mg / ltr
|
KmnO4 Color retention
|
60 minutes
|
UV Absorbance at 254 nm
|
0.007
|
TOC
|
Not detected
|
Endotoxin
|
<0.25 Eu / ml
|
Yeast & Mould
|
Zero
|
Total Plate Count
|
Zero
|
Standard Plate Count
|
Zero
|
Distillate Quality
|
Pyrogen Free
|
Organic Matter
|
NIL
|
Keeping in view customer’s requirements & serviceability of the equipment, Lab Smith is now able to offer the All Quartz Double Distiller with Demountable Boiler. The first boiler of the plant can now be dismantled from the 2nd Boiler and the condensing column making this more user friendly and better serviceability.
Special Advantages of New Demountable Model:
- Extremely easy cleaning of the first boiler since the boiler can be dismantled from the Main Unit. The Ball & Socket has been precision ground for perfect matching and interchangeability.
- Boilers and Condensers have larger boiling space resulting in more balanced boiling and better quality of distillate.
- Larger condensing area. Hence cooler distillate.
- More compact and easy for servicing.
Conductivity :
Conductivity specified applies for freshly prepared water. During storage it is possible for contaminants like atmospheric carbon dioxide and alkalies from glass containers and contaminants from glass containers to be dissolved in water leading to changes in conductivity. Conductivity is affected by temperature and the presence of absorbed carbon dioxide. Test is performed on distilled water free of carbon dioxide at 20ºC.
Note on pH:
Because of difficulties associated with measurement of pH value of high purity water and the doubtful significance of the value obtained, limits for the pH values are not mentioned for Grade 1 and Grade 2 water.
Ordering Information:
Cat. No.
|
Description
|
LAQD - 01 - DB
|
Lab All Quartz Distiller Unit: 01 Ltrs/Hr
|
LAQD – 1.5 - DB
|
Lab All Quartz Distiller Unit: 4.5 Ltrs/Hr
|
LAQD - 02 - DB
|
Lab All Quartz Distiller Unit: 02 Ltrs/Hr
|
LAQD – 2.5 - DB
|
Lab All Quartz Distiller Unit: 2.5 Ltrs/Hr
|
LAQD - 03 - DB
|
Lab All Quartz Distiller Unit: 03 Ltrs/Hr
|
LAQD - 04 - DB
|
Lab All Quartz Distiller Unit: 04 Ltrs/Hr
|
LAQD - 05 - DB
|
Lab All Quartz Distiller Unit: 05 Ltrs/Hr
|
Spares for Above Water Distillation Units:
Cat. No.
|
Description
|
Cat. No.
|
Description
|
LAQD-QB-01
|
Quartz Boiler
|
LAQD-HE-03
|
Heating Element
|
LAQD-QB-1.5
|
Quartz Boiler
|
LAQD-HE-04
|
Heating Element
|
LAQD-QB-02
|
Quartz Boiler
|
LAQD-HE-05
|
Heating Element
|
LAQD-QB-2.5
|
Quartz Boiler
|
LAQD-BC-01
|
Bottom Cup
|
LAQD-QB-03
|
Quartz Boiler
|
LAQD-BC-1.5
|
Bottom Cup
|
LAQD-QB-04
|
Quartz Boiler
|
LAQD-BC-02
|
Bottom Cup
|
LAQD-QB-05
|
Quartz Boiler
|
LAQD-BC-2.5
|
Bottom Cup
|
LAQD-IB-01
|
Integrated Boiler
|
LAQD-BC-03
|
Bottom Cup
|
LAQD-IB-1.5
|
Integrated Boiler
|
LAQD-BC-04
|
Bottom Cup
|
LAQD-IB-02
|
Integrated Boiler
|
LAQD-BC-05
|
Bottom Cup
|
LAQD-IB-2.5
|
Integrated Boiler
|
LAQD-DT-01
|
Delivery Tube
|
LAQD-IB-03
|
Integrated Boiler
|
LAQD-DT-1.5
|
Delivery Tube
|
LAQD-IB-04
|
Integrated Boiler
|
LAQD-DT-02
|
Delivery Tube
|
LAQD-IB-05
|
Integrated Boiler
|
LAQD-DT-2.5
|
Delivery Tube
|
LAQD-HE-01
|
Heating Element
|
LAQD-DT-03
|
Delivery Tube
|
LAQD-HE-1.5
|
Heating Element
|
LAQD-DT-04
|
Delivery Tube
|
LAQD-HE-02
|
Heating Element
|
LAQD-DT-05
|
Delivery Tube
|
LAQD-HE-2.5
|
Heating Element
|
|
|