DESCRIPTION:
RTD Reactions:
Real reactors do not satisfy the idealized flow patterns, back mix flow or plug flow deviation from ideality can be due to channelling of fluid through the vessel, recycling of fluid within the vessel or due to the presence of stagnant region or pockets of fluid in the vessel. To predict the exact behaviour of a vessel as a Chemicals reactor, RTD or stimulus response technique is used.
The setup consists of one feed tank through which water is fed to the reactor. The flow rate can be changed by varying the speed of peristaltic pump. It is a straight tube type plug flow reactor made up of glass. Samples are collected for analysis from the outlet of reactor. For understanding the R.T.D. characteristics, a special arrangement to inject tracer into the lower end of reactor, using a syringe is provided.
EXPERIMENTATION:
- To plot RTD curve for Plug Flow Reactor
- To determine the Dispersion No.
UTILITIES REQUIRED:
- Water Supply.
- Floor Drain.
- Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted.
TECHNICAL DETAILS:
| Reactor |
Material Borosilicate Glass, capacity (0.6-0.7) Ltrs(approx.) |
| Feed Tank |
Material Stainless Steel, Capacity - 20 Ltrs. |
| Feed Circulation |
By Peristaltic Pump (1No.) |
| Tracer Injection |
Special arrangement will be provided with syringe. |
| Piping |
Stainless Steel and PVC. |
| Stop Watch |
Electronic |
| An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus |
| The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint. |
Ordering Details:
| Catalogue No. |
Description |
JICRE-015C
|
RTD STUDIES IN PLUG FLOW TUBULAR REACTOR
(Coiled Tube Type) (Peristaltic Pump Feed System)
|